Product comparison · 2 uninterruptible power supplies (upss)

APC Emergency lighting Galaxy 300 vs CDP R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac

Add a product
  • 22specifications compared
  • 17differ
  • 5identical
  • 51known for one product only

Key differences

  • UPS topology
    • Emergency lighting Galaxy 300:Double-conversion (Online)
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:Line-Interactive
  • Output power capacity
    • Emergency lighting Galaxy 300:30 kVA
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:0.75 kVA
  • Output power
    • Emergency lighting Galaxy 300:20000 W
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:375 W
  • Input operation voltage (min)
    • Emergency lighting Galaxy 300:340 V
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:85 V
  • Input operation voltage (max)
    • Emergency lighting Galaxy 300:460 V
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:154 V
  • Input frequency
    • Emergency lighting Galaxy 300:45/65 Hz
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:50/60 Hz
  • Output operation voltage (min)
    • Emergency lighting Galaxy 300:380 V
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:108 V
  • Output operation voltage (max)
    • Emergency lighting Galaxy 300:415 V
    • R-UPR758 750VA/375W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:132 V

Side by side

Differences highlightedShow differences only (on)
Comparison of G3H30KHT6BX710, R-UPR758
73 specifications
Features10 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers30 kVA0.75 kVA
Output powerDiffers20000 W375 W
Input operation voltage (min)Differs340 V85 V
Input operation voltage (max)Differs460 V154 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs380 V108 V
Output operation voltage (max)Differs415 V132 V
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Surge energy ratingKnown for oneUnknown — not stated by the source300 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Number of input phasesDiffers31
Number of output phasesKnown for oneUnknown — not stated by the source1
Power factorKnown for oneUnknown — not stated by the source0.6
Crest factorDiffers2.5:13:1
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Maximum currentKnown for one47 AUnknown — not stated by the source
EfficiencyKnown for one93%Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelKnown for one54.5 dBUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–15P
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
Power plugKnown for oneTerminalUnknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
Batteryidentical
Battery capacityKnown for oneUnknown — not stated by the source4.5 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source8 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Design1 differ
Product colourDiffersGreyBlack
Cable lengthKnown for oneUnknown — not stated by the source1 m
Display typeKnown for oneLCDUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 35 °C0 - 40 °C
Storage temperature (T-T)Known for one-10 - 60 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 9000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers500 mm105 mm
DepthDiffers860 mm315 mm
HeightDiffers1300 mm138 mm
WeightDiffers200 kg4.6 kg
Packaging data1 differ
Package weightDiffers226 kg4.95 kg
Package widthKnown for one800 mmUnknown — not stated by the source
Package depthKnown for one965 mmUnknown — not stated by the source
Package heightKnown for one1440 mmUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source18.4 kg
Pallet gross heightKnown for oneUnknown — not stated by the source185 cm
Pallet gross lengthKnown for oneUnknown — not stated by the source115 cm
Pallet gross weightKnown for oneUnknown — not stated by the source967.4 kg
Pallet gross widthKnown for oneUnknown — not stated by the source115 cm
Master (outer) case widthKnown for oneUnknown — not stated by the source365 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source568 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source211 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source19.8 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source4 pc(s)
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneCE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUVUnknown — not stated by the source
Other featuresidentical
Type of input protection requiredKnown for onegL fuseUnknown — not stated by the source
BypassKnown for oneBuilt-in Maintenance BypassUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons