Product comparison · 2 uninterruptible power supplies (upss)

APC Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout vs APC Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V

Add a product
  • 21specifications compared
  • 11differ
  • 10identical
  • 2known for one product only

Key differences

The APC Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout has 4.5 kVA more output power capacity than the APC Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V (12 kVA vs 7.5 kVA). The APC Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout has 2,400 W more output power than the APC Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V (8400 W vs 6000 W). The APC Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V has 439.1 kg more package weight than the APC Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout (909.1 kg vs 470 kg). Only the APC Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout has emergency Power Off (EPO). Weight: 446.95 g on the APC Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout, 286.4 kg on the APC Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V.

  • Output power capacity
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:12 kVA
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:7.5 kVA
  • Output power
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:8400 W
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:6000 W
  • Emergency Power Off (EPO)
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:Yes
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:No
  • Weight
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:446.95 g
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:286.4 kg
  • Package weight
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:470 kg
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:909.1 kg
  • Nominal input voltage
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:230-400 V
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:230 V
  • Package dimensions (WxDxH)
    • Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout:749 x 1219 x 2210 mm
    • Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V:749 x 1245 x 2210 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Fully Assembled InfraStruXure System, 12kVA Symmetra LX, Scaleable to 16kVA N+1, 230V Outpout, Fully Assembled InfraStruXure System with 7.5kVA Smart-UPS RT, 230V
23 specifications
Features3 differ
Output power capacityDiffers12 kVA7.5 kVA
Output powerDiffers8400 W6000 W
Emergency Power Off (EPO)DiffersYesNo
Audible alarm(s)YesYes
Batteryidentical
Replacement battery cartridgeKnown for oneSYBT5Unknown — not stated by the source
Design1 differ
Product colourBlackBlack
CompatibilityDiffersC-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,EN 55024,EN 60950,GOST,IEC 60950,VDEC-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,EN 60950,EN 61000-3-2,GOST,PCBC,VDE
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Weight & dimensions1 differ
WeightDiffers446.95 g286.4 kg
Packaging data1 differ
Package weightDiffers470 kg909.1 kg
Other features5 differ
Battery typeLead-AcidLead-Acid
InterfaceDiffersDB-9 RS-232,Smart-SlotDB-9 RS-232,RJ-45 10/100 Base-T,Smart-Slot
Output connectionsKnown for one(1) Hard Wire 3-wire (H N + G) (28) IEC 320 C13 (13) IEC 320 C19Unknown — not stated by the source
Input connection typeDiffersHard Wire 3 wire (1PH+1PH+G)British BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P
Dimensions (WxDxH)597 x 1072 x 2070 mm597 x 1072 x 2070 mm
Nominal input voltageDiffers230-400 V230 V
Nominal output voltage230 V230 V
Package dimensions (WxDxH)Differs749 x 1219 x 2210 mm749 x 1245 x 2210 mm
I/O portsDiffers(1) Hard Wire 3-wire (H N + G) (28) IEC 320 C13 (13) IEC 320 C19 Hard Wire 3 wire (1PH+1PH+G)(1) Hard Wire 3-wire (H N + G) (18) IEC 320 C13 (4) IEC 320 C19 (4) IEC Jumpers British BS1363A IEC-320 C20 Schuko CEE 7/EU1-16P

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons