Product comparison · 2 uninterruptible power supplies (upss)

APC E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA vs Vertiv Liebert Hipulse-U 60kVA

Add a product
  • 12specifications compared
  • 10differ
  • 2identical
  • 29known for one product only

Key differences

The Vertiv Liebert Hipulse-U 60kVA has 40 kVA more output power capacity than the APC E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA (60 kVA vs 20 kVA). The Vertiv Liebert Hipulse-U 60kVA has 200 V more input operation voltage (min) than the APC E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA (380 V vs 180 V). The Vertiv Liebert Hipulse-U 60kVA has 162 V more input operation voltage (max) than the APC E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA (415 V vs 253 V). Input frequency: 45/65 Hz on the APC E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA, 50/60 Hz on the Vertiv Liebert Hipulse-U 60kVA. Form factor: Tower on the APC E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA, Rackmount/Tower on the Vertiv Liebert Hipulse-U 60kVA.

  • Output power capacity
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:20 kVA
    • Liebert Hipulse-U 60kVA:60 kVA
  • Input operation voltage (min)
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:180 V
    • Liebert Hipulse-U 60kVA:380 V
  • Input operation voltage (max)
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:253 V
    • Liebert Hipulse-U 60kVA:415 V
  • Input frequency
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:45/65 Hz
    • Liebert Hipulse-U 60kVA:50/60 Hz
  • Form factor
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:Tower
    • Liebert Hipulse-U 60kVA:Rackmount/Tower
  • Product colour
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:White
    • Liebert Hipulse-U 60kVA:Black
  • Operating temperature (T-T)
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:0 - 40 °C
    • Liebert Hipulse-U 60kVA:0 - 50 °C
  • Width
    • E3SUPS20KFB1 uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:500 mm
    • Liebert Hipulse-U 60kVA:715 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of E3SUPS20KFB1, Liebert Hipulse-U 60kVA
41 specifications
Features4 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers20 kVA60 kVA
Output powerKnown for one20000 WUnknown — not stated by the source
WaveformPure sinePure sine
Input operation voltage (min)Differs180 V380 V
Input operation voltage (max)Differs253 V415 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output frequencyKnown for one60 HzUnknown — not stated by the source
Maximum currentKnown for one68 AUnknown — not stated by the source
Heat dissipationKnown for one1701 BTU/hUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one4%Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery voltageKnown for one120 VUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount/Tower
Product colourDiffersWhiteBlack
Display typeKnown for oneLCDUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 1015.9 mUnknown — not stated by the source
Packaging contentidentical
Management card includedKnown for oneNoUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Certificatesidentical
Compliance certificatesKnown for oneRoHS, CE, EAC, RCMUnknown — not stated by the source
CertificationKnown for oneCE, EAC, IEC 62040-1-1, IEC 62040-2, IEC 62040-3, IEC 62040-4, ISTA 2B, RCM, WEEE, REACHUnknown — not stated by the source
Poweridentical
Input current (max)Known for one68 AUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers500 mm715 mm
DepthDiffers969 mm810 mm
HeightDiffers1400 mm1250 mm
WeightKnown for one158 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one1114 mmUnknown — not stated by the source
Package depthKnown for one683 mmUnknown — not stated by the source
Package heightKnown for one1640 mmUnknown — not stated by the source
Package weightKnown for one195 kgUnknown — not stated by the source
Other featuresidentical
Output voltageKnown for one208 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons