Product comparison · 2 uninterruptible power supplies (upss)

APC CP12044LI uninterruptible power supply (UPS) vs Vertiv Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries

Add a product
  • 9specifications compared
  • 8differ
  • 1identical
  • 24known for one product only

Key differences

The Vertiv Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries has 35,962 W more output power than the APC CP12044LI uninterruptible power supply (UPS) (36000 W vs 38 W). The Vertiv Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries has 403 V more output operation voltage (max) than the APC CP12044LI uninterruptible power supply (UPS) (415 V vs 12 V). The Vertiv Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries has 445 mm more width than the APC CP12044LI uninterruptible power supply (UPS) (600 mm vs 155 mm). Form factor: Compact on the APC CP12044LI uninterruptible power supply (UPS), Tower on the Vertiv Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries. International Protection (IP) code: IP30 on the APC CP12044LI uninterruptible power supply (UPS), IP20 on the Vertiv Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries.

  • Output power
    • CP12044LI uninterruptible power supply (UPS):38 W
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:36000 W
  • Output operation voltage (max)
    • CP12044LI uninterruptible power supply (UPS):12 V
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:415 V
  • Form factor
    • CP12044LI uninterruptible power supply (UPS):Compact
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:Tower
  • International Protection (IP) code
    • CP12044LI uninterruptible power supply (UPS):IP30
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:IP20
  • Width
    • CP12044LI uninterruptible power supply (UPS):155 mm
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:600 mm
  • Depth
    • CP12044LI uninterruptible power supply (UPS):98 mm
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:850 mm
  • Height
    • CP12044LI uninterruptible power supply (UPS):170 mm
    • Liebert NXC 40kVA for parallel 6MIN autonomy with 10y batteries:1600 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of CP12044LI, LI60401C13A1A00
33 specifications
Features2 differ
Output powerDiffers38 W36000 W
Output operation voltage (max)Differs12 V415 V
Maximum currentKnown for one3 AUnknown — not stated by the source
UPS topologyKnown for oneUnknown — not stated by the sourceDouble-conversion (Online)
Output power capacityKnown for oneUnknown — not stated by the source40 kVA
Input operation voltage (min)Known for oneUnknown — not stated by the source305 V
Input operation voltage (max)Known for oneUnknown — not stated by the source477 V
Input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source380 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Noise levelKnown for oneUnknown — not stated by the source58 dB
Batteryidentical
Battery technologyKnown for oneLithiumUnknown — not stated by the source
Design2 differ
Form factorDiffersCompactTower
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeDiffersIP30IP20
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 45 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-5 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDiffersREACH, RoHSEN/IEC/AS 62040-1, EN/IEC/AS 62040-2, VFI-SS-111
Weight & dimensions3 differ
WidthDiffers155 mm600 mm
DepthDiffers98 mm850 mm
HeightDiffers170 mm1600 mm
WeightKnown for one380 gUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for one240 pc(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons