Product comparison · 2 uninterruptible power supplies (upss)

APC BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA vs CDP R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac

Add a product
  • 27specifications compared
  • 18differ
  • 9identical
  • 41known for one product only

Key differences

  • Output power capacity
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:0.8 kVA
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:1 kVA
  • Output power
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:415 W
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:500 W
  • Input operation voltage (min)
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:140 V
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:85 V
  • Input operation voltage (max)
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:300 V
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:145 V
  • Output operation voltage (min)
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:230 V
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:108 V
  • Output operation voltage (max)
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:230 V
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:132 V
  • Surge energy rating
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:273 J
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:300 J
  • Power factor
    • BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA:0.52
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:0.6

Side by side

Differences highlightedShow differences only (off)
Comparison of BX800LI-MS, R-UPR1008
68 specifications
Features8 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers0.8 kVA1 kVA
Output powerDiffers415 W500 W
WaveformSineSine
Input operation voltage (min)Differs140 V85 V
Input operation voltage (max)Differs300 V145 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)Differs230 V108 V
Output operation voltage (max)Differs230 V132 V
Surge energy ratingDiffers273 J300 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Power factorDiffers0.520.6
Crest factorKnown for oneUnknown — not stated by the source3:1
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Surge protectionYesYes
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one7 AUnknown — not stated by the source
Hold time (max)Known for one6 msUnknown — not stated by the source
Hold time (min)Known for one4 msUnknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarm, Overload alarmUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersC13 coupler, C14 coupler, NEMA 5–15PNEMA 5–15R
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
Battery2 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Acid
Battery capacityDiffers81 VAh9 Ah
Battery voltage12 V12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source8 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Battery life (max)Known for one4 year(s)Unknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorKnown for oneUnknown — not stated by the sourceTower
Product colourBlackBlack
Cable lengthDiffers1.22 m1 m
LED indicatorsDiffersBattery replacementYes
Display typeKnown for oneLEDUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 9000 mUnknown — not stated by the source
Packaging contentidentical
ManualYesYes
Weight & dimensions4 differ
WidthDiffers115 mm195 mm
DepthDiffers256 mm355 mm
HeightDiffers200 mm138 mm
WeightDiffers6.5 kg5.45 kg
Packaging data1 differ
Package weightDiffers6.7 kg5.9 kg
Warranty cardKnown for oneYesUnknown — not stated by the source
Package widthKnown for one205 mmUnknown — not stated by the source
Package depthKnown for one345 mmUnknown — not stated by the source
Package heightKnown for one290 mmUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source21.8 kg
Pallet gross heightKnown for oneUnknown — not stated by the source185 cm
Pallet gross lengthKnown for oneUnknown — not stated by the source115 cm
Pallet gross weightKnown for oneUnknown — not stated by the source1151.2 kg
Pallet gross widthKnown for oneUnknown — not stated by the source115 cm
Master (outer) case widthKnown for oneUnknown — not stated by the source365 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source568 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source211 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source23.6 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source4 pc(s)
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneCE, WEEEUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons