Product comparison · 2 uninterruptible power supplies (upss)

APC BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA vs APC G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA

Add a product
  • 29specifications compared
  • 23differ
  • 6identical
  • 32known for one product only

Key differences

  • UPS topology
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:Line-Interactive
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:Double-conversion (Online)
  • Output power capacity
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:0.7 kVA
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:40 kVA
  • Output power
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:390 W
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:36000 W
  • Input operation voltage (min)
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:140 V
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:250 V
  • Input operation voltage (max)
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:300 V
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:477 V
  • Input frequency
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:47/63 Hz
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:45/65 Hz
  • Efficiency
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:95.9%
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:92.8%
  • Noise level
    • BX700U-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:45 dB
    • G55TUPSM40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:55.5 dB

Side by side

Differences highlightedShow differences only (off)
Comparison of BX700U-FR, G55TUPSM40HB15S
61 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers0.7 kVA40 kVA
Output powerDiffers390 W36000 W
WaveformSineSine
Input operation voltage (min)Differs140 V250 V
Input operation voltage (max)Differs300 V477 V
Input frequencyDiffers47/63 Hz45/65 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source380 V
Output operation voltage (max)Known for oneUnknown — not stated by the source415 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentKnown for oneUnknown — not stated by the source190 A
EfficiencyDiffers95.9%92.8%
Power factorKnown for oneUnknown — not stated by the source1
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source1%
Noise levelDiffers45 dB55.5 dB
Web-based managementKnown for oneUnknown — not stated by the sourceYes
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one273 JUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesKnown for oneUnknown — not stated by the sourceHard Wire 4-wire (3PH + G)
Power plugKnown for oneUnknown — not stated by the sourceTerminal
AC outlets quantityDiffers3 AC outlet(s)1 AC outlet(s)
SmartSlotKnown for oneUnknown — not stated by the sourceYes
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Battery2 differ
Battery voltageDiffers12 V432 V
Battery life (max)Known for oneUnknown — not stated by the source10 year(s)
Battery recharge timeDiffers6 h10 h
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery capacityKnown for one7.2 AhUnknown — not stated by the source
Number of batteries supportedKnown for one1Unknown — not stated by the source
Typical backup time at full loadKnown for one1.3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one8.7 minUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Design1 differ
Form factorKnown for oneUnknown — not stated by the sourceTower
Product colourBlackBlack
Display typeDiffersLEDLCD
LED indicatorsYesYes
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Cable lengthKnown for one1.52 mUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 40 °C-20 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 3000 m0 - 999.9 m
Non-operating altitudeDiffers0 - 9000 m0 - 12000 m
Certificates1 differ
CertificationDiffersREACHCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TÜV, VDE
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers115 mm1110 mm
DepthDiffers256 mm850 mm
HeightDiffers200 mm1900 mm
WeightDiffers6 kg975 kg
Packaging data3 differ
Package widthDiffers295 mm1130 mm
Package depthDiffers340 mm960 mm
Package heightDiffers275 mm2030 mm
Package weightKnown for oneUnknown — not stated by the source1065 kg
Bundled softwareKnown for onePowerChuteUnknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceVRLA
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.