Product comparison · 2 uninterruptible power supplies (upss)

APC BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA vs CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA

Add a product
  • 21specifications compared
  • 18differ
  • 3identical
  • 43known for one product only

Key differences

The CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA has 0.2 kVA more output power capacity than the APC BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA (2.2 kVA vs 2 kVA). The CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA has 1,000 W more output power than the APC BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA (2200 W vs 1200 W). The APC BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA has 10 V more input operation voltage (min) than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (120 V vs 110 V). UPS topology: Line-Interactive on the APC BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA, Double-conversion (Online) on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA. Form factor: Desktop on the APC BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA, Rackmount/Tower on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA.

  • UPS topology
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:Line-Interactive
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:Double-conversion (Online)
  • Output power capacity
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2.2 kVA
  • Output power
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:1200 W
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2200 W
  • Input operation voltage (min)
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:120 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:110 V
  • Output operation voltage (min)
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:120 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:200 V
  • Surge energy rating
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:350 J
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:1065 J
  • Battery voltage
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:24 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:72 V
  • Battery recharge time
    • BX2000M-LM uninterruptible power supply (UPS) Line-Interactive 2 kVA:8 h
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:4 h

Side by side

Differences highlightedShow differences only (on)
Comparison of BX2000M-LM, OLS2K2ERT2UH
64 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers2 kVA2.2 kVA
Output powerDiffers1200 W2200 W
WaveformKnown for oneUnknown — not stated by the sourcePure sine
Input operation voltage (min)Differs120 V110 V
Input operation voltage (max)Known for oneUnknown — not stated by the source300 V
Input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output operation voltage (min)Differs120 V200 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentKnown for oneUnknown — not stated by the source10.39 A
Surge energy ratingDiffers350 J1065 J
Heat dissipationKnown for oneUnknown — not stated by the source564 BTU/h
Number of input phasesKnown for oneUnknown — not stated by the source1
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98%
Power factorKnown for oneUnknown — not stated by the source1
Input power factorKnown for oneUnknown — not stated by the source0.99
ECO modeKnown for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement, Fault
Response timeKnown for one6 msUnknown — not stated by the source
Noise levelKnown for one40 dBUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Battery2 differ
Battery voltageDiffers24 V72 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source12 min
Battery recharge timeDiffers8 h4 h
Charging currentKnown for oneUnknown — not stated by the source8 A
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRBP0161
Battery capacityKnown for one9000 mAhUnknown — not stated by the source
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Design1 differ
Form factorDiffersDesktopRackmount/Tower
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Cable lengthKnown for oneUnknown — not stated by the source1.5 m
Control typeKnown for oneUnknown — not stated by the sourceButtons
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions6 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Differs-15 - 40 °C-20 - 50 °C
Operating relative humidity (H-H)Differs0 - 95%20 - 90%
Storage relative humidity (H-H)Differs0 - 95%10 - 90%
Operating altitudeDiffers0 - 3000 m0 - 1500 m
Non-operating altitudeDiffers0 - 3000 m0 - 1500 m
Weight & dimensions3 differ
WidthDiffers140 mm540 mm
DepthDiffers390 mm730 mm
HeightDiffers190 mm230 mm
WeightKnown for one12.3 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one235 mmUnknown — not stated by the source
Package depthKnown for one495 mmUnknown — not stated by the source
Package heightKnown for one297 mmUnknown — not stated by the source
Package weightKnown for one13.3 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons