Key differences

The Legrand Keor HPE has 78.5 kVA more output power capacity than the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (80 kVA vs 1.5 kVA). The Legrand Keor HPE has 79,100 W more output power than the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (80000 W vs 900 W). The Legrand Keor HPE has 265 V more output operation voltage (min) than the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (380 V vs 115 V). UPS topology: Line-Interactive on the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, Double-conversion (Online) on the Legrand Keor HPE. Input frequency: 57/63 Hz on the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 45/65 Hz on the Legrand Keor HPE.

  • UPS topology
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
    • Keor HPE:Double-conversion (Online)
  • Output power capacity
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • Keor HPE:80 kVA
  • Output power
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
    • Keor HPE:80000 W
  • Input frequency
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:57/63 Hz
    • Keor HPE:45/65 Hz
  • Output operation voltage (min)
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:115 V
    • Keor HPE:380 V
  • Number of input phases
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1
    • Keor HPE:3
  • Number of output phases
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1
    • Keor HPE:3
  • Noise level
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:45 dB
    • Keor HPE:60 dB

Side by side

Differences highlightedShow differences only (on)
Comparison of BX1500BI-BR, Keor HPE
51 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.5 kVA80 kVA
Output powerDiffers900 W80000 W
WaveformKnown for oneSimulated sineUnknown — not stated by the source
Input frequencyDiffers57/63 Hz45/65 Hz
Output operation voltage (min)Differs115 V380 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one224 JUnknown — not stated by the source
Number of input phasesDiffers13
Number of output phasesDiffers13
Power factorKnown for one0.6Unknown — not stated by the source
Noise levelDiffers45 dB60 dB
Surge protectionKnown for oneYesUnknown — not stated by the source
Input operation voltage (min)Known for oneUnknown — not stated by the source320 V
Input operation voltage (max)Known for oneUnknown — not stated by the source480 V
Output operation voltage (max)Known for oneUnknown — not stated by the source415 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
EfficiencyKnown for oneUnknown — not stated by the source95%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source99%
Output power factorKnown for oneUnknown — not stated by the source1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneNBR 14136Unknown — not stated by the source
AC outlets quantityKnown for one7 AC outlet(s)Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Typical backup time at full loadKnown for one1 minUnknown — not stated by the source
Typical backup time at half loadKnown for one4 minUnknown — not stated by the source
Battery life (max)Known for one2 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one6 hUnknown — not stated by the source
Design1 differ
Form factorKnown for oneTowerUnknown — not stated by the source
Product colourDiffersBlackWhite, Black
Cable lengthKnown for one1.1 mUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
LED indicatorsKnown for oneBattery levelUnknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 40 °C-20 - 50 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers125 mm560 mm
DepthDiffers380 mm940 mm
HeightDiffers225 mm1500 mm
WeightDiffers12.3 kg250 kg
Packaging dataidentical
Package widthKnown for one194 mmUnknown — not stated by the source
Package depthKnown for one488 mmUnknown — not stated by the source
Package heightKnown for one314 mmUnknown — not stated by the source
Package weightKnown for one13.4 kgUnknown — not stated by the source