Product comparison · 2 uninterruptible power supplies (upss)

APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA

Add a product
  • 12specifications compared
  • 11differ
  • 1identical
  • 32known for one product only

Key differences

The Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA has 0.5 kVA more output power capacity than the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2 kVA vs 1.5 kVA). The Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA has 1,100 W more output power than the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2000 W vs 900 W). The Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA has 315 mm more width than the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (440 mm vs 125 mm). UPS topology: Line-Interactive on the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, Double-conversion (Online) on the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA. Waveform: Simulated sine on the APC BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, Sine on the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA.

  • UPS topology
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Double-conversion (Online)
  • Output power capacity
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2 kVA
  • Output power
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2000 W
  • Waveform
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Simulated sine
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Sine
  • Input frequency
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:57/63 Hz
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:50/60 Hz
  • Form factor
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Tower
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Rackmount/Tower
  • Product colour
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Black
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:White, Black
  • Width
    • BX1500BI-BR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:125 mm
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:440 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of BX1500BI-BR, Keor-DK-2000-B
44 specifications
Features5 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.5 kVA2 kVA
Output powerDiffers900 W2000 W
WaveformDiffersSimulated sineSine
Input frequencyDiffers57/63 Hz50/60 Hz
Output operation voltage (min)Known for one115 VUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one224 JUnknown — not stated by the source
Number of input phasesKnown for one1Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Power factorKnown for one0.6Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Input operation voltage (min)Known for oneUnknown — not stated by the source230 V
Input operation voltage (max)Known for oneUnknown — not stated by the source230 V
Ports & interfacesidentical
AC outlet typesKnown for oneNBR 14136Unknown — not stated by the source
AC outlets quantity7 AC outlet(s)7 AC outlet(s)
Batteryidentical
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Typical backup time at full loadKnown for one1 minUnknown — not stated by the source
Typical backup time at half loadKnown for one4 minUnknown — not stated by the source
Battery life (max)Known for one2 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one6 hUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount/Tower
Product colourDiffersBlackWhite, Black
Cable lengthKnown for one1.1 mUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
LED indicatorsKnown for oneBattery levelUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers125 mm440 mm
DepthDiffers380 mm640 mm
HeightDiffers225 mm88 mm
WeightDiffers12.3 kg24 kg
Packaging dataidentical
Package widthKnown for one194 mmUnknown — not stated by the source
Package depthKnown for one488 mmUnknown — not stated by the source
Package heightKnown for one314 mmUnknown — not stated by the source
Package weightKnown for one13.4 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.