Product comparison · 2 uninterruptible power supplies (upss)

APC BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA vs CyberPower PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA

Add a product
  • 14specifications compared
  • 9differ
  • 5identical
  • 33known for one product only

Key differences

The APC BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA has 0.35 kVA more output power capacity than the CyberPower PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA (1.1 kVA vs 0.75 kVA). The APC BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA has 135 W more output power than the CyberPower PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA (660 W vs 525 W). The APC BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA has 7 V more input operation voltage (min) than the CyberPower PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA (82 V vs 75 V). Input frequency: 50/60 Hz on the APC BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA, 47/63 Hz on the CyberPower PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA. AC outlet types: NEMA 5–15R on the APC BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA, NEMA 5–15P on the CyberPower PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA.

  • Output power capacity
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:1.1 kVA
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:0.75 kVA
  • Output power
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:660 W
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:525 W
  • Input operation voltage (min)
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:82 V
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:75 V
  • Input operation voltage (max)
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:148 V
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:154 V
  • Input frequency
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:50/60 Hz
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:47/63 Hz
  • AC outlet types
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:NEMA 5–15R
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:NEMA 5–15P
  • Typical backup time at half load
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:80 min
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:3 min
  • Operating relative humidity (H-H)
    • BX1100CI-LM uninterruptible power supply (UPS) 1.1 kVA:0 - 95%
    • PR750LCDTAA uninterruptible power supply (UPS) 0.75 kVA:0 - 90%

Side by side

Differences highlightedShow differences only (on)
Comparison of BX1100CI-LM, PR750LCDTAA
47 specifications
Features5 differ
Output power capacityDiffers1.1 kVA0.75 kVA
Output powerDiffers660 W525 W
Input operation voltage (min)Differs82 V75 V
Input operation voltage (max)Differs148 V154 V
Input frequencyDiffers50/60 Hz47/63 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source120 V
Output operation voltage (max)Known for oneUnknown — not stated by the source120 V
Surge energy ratingKnown for oneUnknown — not stated by the source1030 J
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceBattery replacement
Maximum currentKnown for one9 AUnknown — not stated by the source
EfficiencyKnown for one97%Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersNEMA 5–15RNEMA 5–15P
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Number of output IEC jumpersKnown for one1Unknown — not stated by the source
Battery1 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Number of battery cellsKnown for oneUnknown — not stated by the source2
Typical backup time at full loadKnown for oneUnknown — not stated by the source15 min
Typical backup time at half loadDiffers80 min3 min
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRB1270X2B
Designidentical
Form factorKnown for oneUnknown — not stated by the sourceTower
Cable lengthKnown for oneUnknown — not stated by the source1.83 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneUnknown — not stated by the sourcePower, Power fail, Battery replacement
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 9000 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, EN/IEC, GOST, NEMKOFCC DOC A
Packaging dataidentical
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel Business Edition
Package weightKnown for one12.9 kgUnknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the source12V/7AH
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Package dimensions (WxDxH)Known for one245 x 440 x 295 mmUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one130 mmUnknown — not stated by the source
DepthKnown for one336 mmUnknown — not stated by the source
HeightKnown for one215 mmUnknown — not stated by the source
WeightKnown for one12 kgUnknown — not stated by the source