Product comparison · 2 uninterruptible power supplies (upss)

APC BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA vs CyberPower OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA

Add a product
  • 19specifications compared
  • 12differ
  • 7identical
  • 36known for one product only

Key differences

  • Output power capacity
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:1.1 kVA
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
  • Output power
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:660 W
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1320 W
  • Input operation voltage (min)
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:150 V
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:90 V
  • Input operation voltage (max)
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:280 V
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:140 V
  • Output operation voltage (min)
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:230 V
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:120 V
  • Output operation voltage (max)
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:230 V
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:120 V
  • Surge energy rating
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:273 J
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1840 J
  • Cable length
    • BX1100CI-GR uninterruptible power supply (UPS) 1.1 kVA:1.16 m
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:6 m

Side by side

Differences highlightedShow differences only (on)
Comparison of BX1100CI-GR, OR2200LCDRT2U
55 specifications
Features7 differ
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output power capacityDiffers1.1 kVA2 kVA
Output powerDiffers660 W1320 W
Input operation voltage (min)Differs150 V90 V
Input operation voltage (max)Differs280 V140 V
Output operation voltage (min)Differs230 V120 V
Output operation voltage (max)Differs230 V120 V
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Surge energy ratingDiffers273 J1840 J
Response timeKnown for oneUnknown — not stated by the source10 ms
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceCoax, Network, Telephone
Maximum currentKnown for one5 AUnknown — not stated by the source
EfficiencyKnown for one97%Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–20R
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-20P
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Batteryidentical
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13 min
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorKnown for oneUnknown — not stated by the sourceRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthDiffers1.16 m6 m
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneStatusUnknown — not stated by the source
Operational conditionsidentical
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778, cUL, CSAC22.2, 107.1, FCC DOC Class B
Weight & dimensions4 differ
WidthDiffers130 mm438.1 mm
DepthDiffers336 mm400 mm
HeightDiffers215 mm88.9 mm
WeightDiffers12 kg23.9 kg
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceRB1290X4G
Packaging dataidentical
Package widthKnown for one245 mmUnknown — not stated by the source
Package depthKnown for one440 mmUnknown — not stated by the source
Package heightKnown for one295 mmUnknown — not stated by the source
Package weightKnown for one12.9 kgUnknown — not stated by the source