Product comparison · 2 uninterruptible power supplies (upss)

APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA vs Salicru SLC 10000 TWIN RT3 MULTI B0

Add a product
  • 20specifications compared
  • 18differ
  • 2identical
  • 54known for one product only

Key differences

The Salicru SLC 10000 TWIN RT3 MULTI B0 has 8.8 kVA more output power capacity than the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA (10 kVA vs 1.2 kVA). The Salicru SLC 10000 TWIN RT3 MULTI B0 has 9,280 W more output power than the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA (10000 W vs 720 W). The Salicru SLC 10000 TWIN RT3 MULTI B0 has 105 V more output operation voltage (min) than the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA (220 V vs 115 V). UPS topology: Line-Interactive on the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA, Double-conversion (Online) on the Salicru SLC 10000 TWIN RT3 MULTI B0. Input frequency: 57/63 Hz on the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA, 50/60 Hz on the Salicru SLC 10000 TWIN RT3 MULTI B0.

  • UPS topology
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:Line-Interactive
    • SLC 10000 TWIN RT3 MULTI B0:Double-conversion (Online)
  • Output power capacity
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:1.2 kVA
    • SLC 10000 TWIN RT3 MULTI B0:10 kVA
  • Output power
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:720 W
    • SLC 10000 TWIN RT3 MULTI B0:10000 W
  • Input frequency
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:57/63 Hz
    • SLC 10000 TWIN RT3 MULTI B0:50/60 Hz
  • Output operation voltage (min)
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:115 V
    • SLC 10000 TWIN RT3 MULTI B0:220 V
  • Number of input phases
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:1
    • SLC 10000 TWIN RT3 MULTI B0:3
  • Number of output phases
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:1
    • SLC 10000 TWIN RT3 MULTI B0:3
  • Noise level
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:45 dB
    • SLC 10000 TWIN RT3 MULTI B0:60 dB

Side by side

Differences highlightedShow differences only (on)
Comparison of BVX1200BI-BR, SLC 10000 TWIN RT3 MULTI B0
74 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.2 kVA10 kVA
Output powerDiffers720 W10000 W
Input operation voltage (min)Known for oneUnknown — not stated by the source110 V
Input operation voltage (max)Known for oneUnknown — not stated by the source300 V
Input frequencyDiffers57/63 Hz50/60 Hz
Output operation voltage (min)Differs115 V220 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output voltage regulationKnown for oneUnknown — not stated by the source1%
Number of input phasesDiffers13
Number of output phasesDiffers13
Efficiency (On-line mode)Known for oneUnknown — not stated by the source95%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98%
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Noise levelDiffers45 dB60 dB
Power protection featuresKnown for oneUnknown — not stated by the sourceOver voltage, Under voltage, Overheating
Maximum number of paralleling UPSsKnown for oneUnknown — not stated by the source3
Input frequency converterKnown for oneUnknown — not stated by the sourceYes
WaveformKnown for oneSimulated sineUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one11.86 AUnknown — not stated by the source
Surge energy ratingKnown for one224 JUnknown — not stated by the source
Power factorKnown for one0.6Unknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Ports & interfacesidentical
USB portKnown for oneUnknown — not stated by the sourceYes
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
RS-232 portsKnown for oneUnknown — not stated by the source1
Parallel ports quantityKnown for oneUnknown — not stated by the source1
HDMI ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
SmartSlotKnown for oneUnknown — not stated by the sourceYes
AC outlet typesKnown for oneNBR 14136Unknown — not stated by the source
AC outlets quantityKnown for one6 AC outlet(s)Unknown — not stated by the source
Battery2 differ
Battery technologyDiffersLead-AcidLead-Calcium (Pb-Ca)
Number of batteries supportedKnown for oneUnknown — not stated by the source6
Battery recharge timeDiffers6 h3 h
Charging currentKnown for oneUnknown — not stated by the source13 A
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one24 VUnknown — not stated by the source
Typical backup time at full loadKnown for one1 minUnknown — not stated by the source
Typical backup time at half loadKnown for one6 minUnknown — not stated by the source
Battery life (max)Known for one2 year(s)Unknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount/Tower
Control typeDiffersButtonsTouch
Display typeKnown for oneUnknown — not stated by the sourceLCD
Cable lengthKnown for one1.1 mUnknown — not stated by the source
LED indicatorsKnown for oneBattery levelUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Operating altitudeDiffers0 - 3000 m0 - 4000 m
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers125 mm438 mm
DepthDiffers380 mm592 mm
HeightDiffers225 mm129 mm
WeightDiffers11.5 kg23.8 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one194 mmUnknown — not stated by the source
Package depthKnown for one488 mmUnknown — not stated by the source
Package heightKnown for one314 mmUnknown — not stated by the source
Package weightKnown for one12.5 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.