Key differences

The CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA has 0.8 kVA more output power capacity than the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA (2 kVA vs 1.2 kVA). The CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA has 1,280 W more output power than the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA (2000 W vs 720 W). The CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA has 85 V more output operation voltage (min) than the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA (200 V vs 115 V). Waveform: Simulated sine on the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA, Pure sine on the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA. Input frequency: 57/63 Hz on the APC BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA, 50/60 Hz on the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA.

  • Output power capacity
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:1.2 kVA
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
  • Output power
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:720 W
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:2000 W
  • Waveform
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:Simulated sine
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:Pure sine
  • Input frequency
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:57/63 Hz
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:50/60 Hz
  • Output operation voltage (min)
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:115 V
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:200 V
  • Noise level
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:45 dB
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:38.5 dB
  • AC outlet types
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:NBR 14136
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:C13 coupler
  • AC outlets quantity
    • BVX1200BI-BR uninterruptible power supply (UPS) Line-Interactive 1.2 kVA:6 AC outlet(s)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:10 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of BVX1200BI-BR, PR2000ERTXL2UC
57 specifications
Features6 differ
Output power capacityDiffers1.2 kVA2 kVA
Output powerDiffers720 W2000 W
WaveformDiffersSimulated sinePure sine
Input operation voltage (min)Known for oneUnknown — not stated by the source131 V
Input operation voltage (max)Known for oneUnknown — not stated by the source302 V
Input frequencyDiffers57/63 Hz50/60 Hz
Output operation voltage (min)Differs115 V200 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Noise levelDiffers45 dB38.5 dB
Power protection featuresKnown for oneUnknown — not stated by the sourceOvercharge, Overload, Surge protection
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one11.86 AUnknown — not stated by the source
Surge energy ratingKnown for one224 JUnknown — not stated by the source
Power factorKnown for one0.6Unknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNBR 14136C13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityDiffers6 AC outlet(s)10 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
Battery3 differ
Typical backup time at full loadDiffers1 min4 min
Typical backup time at half loadDiffers6 min12 min
Battery recharge timeDiffers6 h3 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRBP0129
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one24 VUnknown — not stated by the source
Battery life (max)Known for one2 year(s)Unknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount/Tower
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsDiffersBattery levelPower, Fault
Cable lengthKnown for one1.1 mUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 40 °C-15 - 45 °C
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, Federal Communications Commission (FCC), cUL, UL, VCCI, RoHS
Weight & dimensions4 differ
WidthDiffers125 mm433 mm
DepthDiffers380 mm500 mm
HeightDiffers225 mm86.5 mm
WeightDiffers11.5 kg3.44 kg
Packaging data4 differ
Package widthDiffers194 mm560 mm
Package depthDiffers488 mm620 mm
Package heightDiffers314 mm275 mm
Package weightDiffers12.5 kg4.13 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.