Product comparison · 2 uninterruptible power supplies (upss)

APC BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA vs Vertiv Liebert GXT MT CX

Add a product
  • 25specifications compared
  • 21differ
  • 4identical
  • 36known for one product only

Key differences

The Vertiv Liebert GXT MT CX has 2.1 kVA more output power capacity than the APC BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA (3 kVA vs 0.9 kVA). The Vertiv Liebert GXT MT CX has 1,920 W more output power than the APC BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA (2400 W vs 480 W). The APC BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA has 110 V more input operation voltage (min) than the Vertiv Liebert GXT MT CX (220 V vs 110 V). Only the Vertiv Liebert GXT MT CX has emergency Power Off (EPO). Only the Vertiv Liebert GXT MT CX has USB port.

  • UPS topology
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:Line-Interactive
    • Liebert GXT MT CX:Double-conversion (Online)
  • Output power capacity
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:0.9 kVA
    • Liebert GXT MT CX:3 kVA
  • Output power
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:480 W
    • Liebert GXT MT CX:2400 W
  • Waveform
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:Sine
    • Liebert GXT MT CX:Sine/Pure sine
  • Input operation voltage (min)
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:220 V
    • Liebert GXT MT CX:110 V
  • Input operation voltage (max)
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:240 V
    • Liebert GXT MT CX:280 V
  • Input frequency
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:50/60 Hz
    • Liebert GXT MT CX:40 - 70 Hz
  • Output operation voltage (min)
    • BVG900I-GR uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:230 V
    • Liebert GXT MT CX:200 V

Side by side

Differences highlightedShow differences only (on)
Comparison of BVG900I-GR, Liebert GXT MT CX
61 specifications
Features13 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers0.9 kVA3 kVA
Output powerDiffers480 W2400 W
WaveformDiffersSineSine/Pure sine
Input operation voltage (min)Differs220 V110 V
Input operation voltage (max)Differs240 V280 V
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output operation voltage (min)Differs230 V200 V
Output operation voltage (max)Differs230 V240 V
Output voltage regulationKnown for one10%Unknown — not stated by the source
Surge energy ratingKnown for one156 JUnknown — not stated by the source
Response timeKnown for one6 msUnknown — not stated by the source
Number of input phasesKnown for one1Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO)DiffersNoYes
Noise levelDiffers40 dB45 dB
Power protection featuresDiffersShort circuitOverload
Audible alarm modesDiffersAlarm when on battery, Low battery alarmFault, Low battery alarm
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
EfficiencyKnown for oneUnknown — not stated by the source90%
Input power factorKnown for oneUnknown — not stated by the source0.99
Crest factorKnown for oneUnknown — not stated by the source3:1
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlet typesKnown for oneCEEUnknown — not stated by the source
AC outlets quantityKnown for one2 AC outlet(s)Unknown — not stated by the source
USB portDiffersNoYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one0.0166667 minUnknown — not stated by the source
Typical backup time at half loadKnown for one3.48 minUnknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Number of battery cellsKnown for oneUnknown — not stated by the source6
Charging currentKnown for oneUnknown — not stated by the source16 A
Design2 differ
Form factorDiffersDesktopTower
LED indicatorsDiffersYesFault, Power
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeKnown for oneUnknown — not stated by the sourceLCD
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCBUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers101 mm145 mm
DepthDiffers300 mm397 mm
HeightDiffers142 mm333 mm
WeightDiffers4.9 kg9.8 kg
Packaging dataidentical
Package widthKnown for one101 mmUnknown — not stated by the source
Package depthKnown for one300 mmUnknown — not stated by the source
Package heightKnown for one142 mmUnknown — not stated by the source
Package weightKnown for one4.9 kgUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceIndia

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons