Product comparison · 2 uninterruptible power supplies (upss)

APC BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA vs APC SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA

Add a product
  • 35specifications compared
  • 25differ
  • 10identical
  • 15known for one product only

Key differences

The APC SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA has 2.3 kVA more output power capacity than the APC BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA (3 kVA vs 0.7 kVA). The APC SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA has 1,740 W more output power than the APC BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA (2100 W vs 360 W). The APC BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA has 135 V more input operation voltage (min) than the APC SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA (220 V vs 85 V). Only the APC SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA has USB port. Input frequency: 50/60 Hz on the APC BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA, 45/65 Hz on the APC SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA.

  • Output power capacity
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:0.7 kVA
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 kVA
  • Output power
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:360 W
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:2100 W
  • Input operation voltage (min)
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:220 V
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:85 V
  • Input operation voltage (max)
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:240 V
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:145 V
  • Input frequency
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:50/60 Hz
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:45/65 Hz
  • Output operation voltage (max)
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:230 V
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:115 V
  • Surge energy rating
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:156 J
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:150 J
  • Response time
    • BVG700I-MSX uninterruptible power supply (UPS) Line-Interactive 0.7 kVA:6 ms
    • SMV3000CA-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:2 ms

Side by side

Differences highlightedShow differences only (on)
Comparison of BVG700I-MSX, SMV3000CA-BR
50 specifications
Features10 differ
Output power capacityDiffers0.7 kVA3 kVA
Output powerDiffers360 W2100 W
Input operation voltage (min)Differs220 V85 V
Input operation voltage (max)Differs240 V145 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (max)Differs230 V115 V
Output voltage regulationKnown for one10%Unknown — not stated by the source
Surge energy ratingDiffers156 J150 J
Response timeDiffers6 ms2 ms
Number of input phasesKnown for one1Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneNoUnknown — not stated by the source
Noise levelDiffers40 dB45 dB
Power protection featuresKnown for oneShort circuitUnknown — not stated by the source
Audible alarm modesDiffersAlarm when on battery, Low battery alarmAlarm when on battery, Overload alarm
Output operation voltage (min)Known for oneUnknown — not stated by the source115 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Crest factorKnown for oneUnknown — not stated by the source3:1
Ports & interfaces3 differ
AC outlet typesDiffersCEENBR 14136
AC outlets quantityDiffers2 AC outlet(s)6 AC outlet(s)
USB portDiffersNoYes
Serial ports quantityKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Acid
Typical backup time at full loadKnown for one0.0166667 minUnknown — not stated by the source
Typical backup time at half loadKnown for one4.36 minUnknown — not stated by the source
Battery voltageKnown for oneUnknown — not stated by the source48 V
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Design1 differ
Form factorDiffersDesktopCompact
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions2 differ
Storage temperature (T-T)Differs-15 - 45 °C-10 - 40 °C
Non-operating altitudeDiffers0 - 3000 m0 - 15000 m
Certificatesidentical
Compliance certificatesKnown for oneCBUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers101 mm180 mm
DepthDiffers300 mm455 mm
HeightDiffers142 mm240 mm
WeightDiffers4.2 kg25.4 kg
Packaging data4 differ
Package widthDiffers101 mm592 mm
Package depthDiffers300 mm317 mm
Package heightDiffers142 mm410 mm
Package weightDiffers4.2 kg34 kg