Product comparison · 2 uninterruptible power supplies (upss)

APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA vs Legrand Keor HPE

Add a product
  • 17specifications compared
  • 15differ
  • 2identical
  • 34known for one product only

Key differences

The Legrand Keor HPE has 77.8 kVA more output power capacity than the APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA (80 kVA vs 2.2 kVA). The Legrand Keor HPE has 78,800 W more output power than the APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA (80000 W vs 1200 W). The Legrand Keor HPE has 100 V more input operation voltage (min) than the APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA (320 V vs 220 V). Only the Legrand Keor HPE has emergency Power Off (EPO). UPS topology: Line-Interactive on the APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA, Double-conversion (Online) on the Legrand Keor HPE.

  • UPS topology
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Line-Interactive
    • Keor HPE:Double-conversion (Online)
  • Output power capacity
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
    • Keor HPE:80 kVA
  • Output power
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1200 W
    • Keor HPE:80000 W
  • Input operation voltage (min)
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:220 V
    • Keor HPE:320 V
  • Input operation voltage (max)
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:240 V
    • Keor HPE:480 V
  • Input frequency
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:50/60 Hz
    • Keor HPE:45/65 Hz
  • Output operation voltage (max)
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:230 V
    • Keor HPE:415 V
  • Emergency Power Off (EPO)
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:No
    • Keor HPE:Yes

Side by side

Differences highlightedShow differences only (on)
Comparison of BVG2200I-MSX, Keor HPE
51 specifications
Features9 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers2.2 kVA80 kVA
Output powerDiffers1200 W80000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs220 V320 V
Input operation voltage (max)Differs240 V480 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (max)Differs230 V415 V
Output voltage regulationKnown for one10%Unknown — not stated by the source
Surge energy ratingKnown for one156 JUnknown — not stated by the source
Response timeKnown for one6 msUnknown — not stated by the source
Emergency Power Off (EPO)DiffersNoYes
Noise levelDiffers45 dB60 dB
Power protection featuresKnown for oneShort circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Output operation voltage (min)Known for oneUnknown — not stated by the source380 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
EfficiencyKnown for oneUnknown — not stated by the source95%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source99%
Output power factorKnown for oneUnknown — not stated by the source1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneCEEUnknown — not stated by the source
AC outlets quantityKnown for one4 AC outlet(s)Unknown — not stated by the source
USB portKnown for oneNoUnknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one0.5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one4 minUnknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Design1 differ
Form factorKnown for oneDesktopUnknown — not stated by the source
Product colourDiffersBlackWhite, Black
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 45 °C-20 - 50 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCBUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers130 mm560 mm
DepthDiffers320 mm940 mm
HeightDiffers182 mm1500 mm
WeightDiffers10.6 kg250 kg
Packaging dataidentical
Package widthKnown for one130 mmUnknown — not stated by the source
Package depthKnown for one320 mmUnknown — not stated by the source
Package heightKnown for one182 mmUnknown — not stated by the source
Package weightKnown for one10.6 kgUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.