Product comparison · 2 uninterruptible power supplies (upss)

APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA vs APC SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA

Add a product
  • 31specifications compared
  • 19differ
  • 12identical
  • 16known for one product only

Key differences

The APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 1.7 kVA more output power capacity than the APC SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA (2.2 kVA vs 0.5 kVA). The APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 900 W more output power than the APC SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA (1200 W vs 300 W). The APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 100 V more input operation voltage (min) than the APC SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA (220 V vs 120 V). Only the APC SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA has USB port. AC outlet types: CEE on the APC BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA, NEMA 5-15R, NEMA 5-15P on the APC SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA.

  • Output power capacity
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:0.5 kVA
  • Output power
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1200 W
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:300 W
  • Input operation voltage (min)
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:220 V
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:120 V
  • Surge energy rating
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:156 J
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:400 J
  • Noise level
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:45 dB
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:40 dB
  • AC outlet types
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:CEE
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:NEMA 5-15R, NEMA 5-15P
  • USB port
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:No
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:Yes
  • Battery technology
    • BVG2200I-MSX uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Sealed Lead Acid (VRLA)
    • SC500RM1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:Lead-Acid

Side by side

Differences highlightedShow differences only (on)
Comparison of BVG2200I-MSX, SC500RM1U
47 specifications
Features5 differ
Output power capacityDiffers2.2 kVA0.5 kVA
Output powerDiffers1200 W300 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs220 V120 V
Input operation voltage (max)Known for one240 VUnknown — not stated by the source
Output operation voltage (max)Known for one230 VUnknown — not stated by the source
Output voltage regulationKnown for one10%Unknown — not stated by the source
Surge energy ratingDiffers156 J400 J
Emergency Power Off (EPO)Known for oneNoUnknown — not stated by the source
Noise levelDiffers45 dB40 dB
Power protection featuresKnown for oneShort circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Output operation voltage (min)Known for oneUnknown — not stated by the source120 V
Ports & interfaces2 differ
AC outlet typesDiffersCEENEMA 5-15R, NEMA 5-15P
USB portDiffersNoYes
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
Battery1 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Acid
Typical backup time at full loadKnown for one0.5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one4 minUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Battery recharge timeKnown for oneUnknown — not stated by the source5 h
Design1 differ
Form factorDiffersDesktopRackmount
Operational conditions2 differ
Storage temperature (T-T)Differs-15 - 45 °C-15 - 40 °C
Non-operating altitudeDiffers0 - 3000 m0 - 15240 m
Certificatesidentical
Compliance certificatesKnown for oneCBUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers130 mm440 mm
DepthDiffers320 mm268 mm
HeightDiffers182 mm44 mm
WeightDiffers10.6 kg8.1 kg
Packaging data4 differ
Package widthDiffers130 mm500 mm
Package depthDiffers320 mm333 mm
Package heightDiffers182 mm140 mm
Package weightDiffers10.6 kg8.7 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons