Product comparison · 2 uninterruptible power supplies (upss)

APC BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs APC BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA

Add a product
  • 32specifications compared
  • 20differ
  • 12identical
  • 25known for one product only

Key differences

The APC BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 0.7 kVA more output power capacity than the APC BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2.2 kVA vs 1.5 kVA). The APC BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 420 W more output power than the APC BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (1320 W vs 900 W). The APC BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 856 J more surge energy rating than the APC BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA (1080 J vs 224 J). Waveform: Sine on the APC BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, Simulated sine on the APC BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA. Input frequency: 60 Hz on the APC BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 57/63 Hz on the APC BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA.

  • Output power capacity
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
  • Output power
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1320 W
  • Waveform
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Sine
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Simulated sine
  • Input frequency
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:60 Hz
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:57/63 Hz
  • Surge energy rating
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1080 J
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:224 J
  • AC outlet types
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5-15R
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:NBR 14136
  • AC outlets quantity
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:10 AC outlet(s)
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:7 AC outlet(s)
  • Battery life (max)
    • BR1500MS2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:5 year(s)
    • BX2200I-BR uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2 year(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of BR1500MS2, BX2200I-BR
57 specifications
Features5 differ
Output power capacityDiffers1.5 kVA2.2 kVA
Output powerDiffers900 W1320 W
WaveformDiffersSineSimulated sine
Input operation voltage (max)Known for one120 VUnknown — not stated by the source
Input frequencyDiffers60 Hz57/63 Hz
Output frequencyKnown for one60 HzUnknown — not stated by the source
Maximum currentKnown for one12 AUnknown — not stated by the source
Surge energy ratingDiffers1080 J224 J
Response timeKnown for one6 msUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Output operation voltage (min)Known for oneUnknown — not stated by the source115 V
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Power factorKnown for oneUnknown — not stated by the source0.6
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5-15RNBR 14136
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityDiffers10 AC outlet(s)7 AC outlet(s)
USB port typeKnown for oneUSB Type A/USB Type-CUnknown — not stated by the source
Battery2 differ
Battery replacement accessibilityKnown for oneEnd-userUnknown — not stated by the source
Battery life (max)Differs5 year(s)2 year(s)
Battery recharge timeDiffers16 h6 h
Replacement battery cartridgeKnown for oneAPCRBC163Unknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source24 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source1 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source4 min
Design1 differ
Housing materialKnown for oneAluminiumUnknown — not stated by the source
Cable lengthDiffers1.8288 m1.1 m
Control typeKnown for oneUnknown — not stated by the sourceButtons
LED indicatorsKnown for oneUnknown — not stated by the sourceBattery level
Operational conditions2 differ
Operating altitudeDiffers0 - 914 m0 - 3000 m
Non-operating altitudeDiffers0 - 1524 m0 - 3000 m
Packaging contentidentical
Rack mount kitKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers100 mm125 mm
DepthDiffers368 mm380 mm
HeightDiffers260 mm225 mm
WeightDiffers12.5 kg13.4 kg
Packaging data4 differ
Package widthDiffers482 mm194 mm
Package depthDiffers223 mm488 mm
Package heightDiffers358.7 mm314 mm
Package weightDiffers14.2 kg14.3 kg