Product comparison · 2 uninterruptible power supplies (upss)

APC Power Saving Back-UPS RS 1500 vs APC Symmetra PX 64kW Scalable to 96kW

Add a product
  • 19specifications compared
  • 13differ
  • 6identical
  • 23known for one product only

Key differences

  • Output power capacity
    • Power Saving Back-UPS RS 1500:1.5 kVA
    • Symmetra PX 64kW Scalable to 96kW:64 kVA
  • Output power
    • Power Saving Back-UPS RS 1500:865 W
    • Symmetra PX 64kW Scalable to 96kW:64000 W
  • Battery recharge time
    • Power Saving Back-UPS RS 1500:8 h
    • Symmetra PX 64kW Scalable to 96kW:3.50 h
  • Storage temperature (T-T)
    • Power Saving Back-UPS RS 1500:-15 - 45 °C
    • Symmetra PX 64kW Scalable to 96kW:-15 - 40 °C
  • Operating altitude
    • Power Saving Back-UPS RS 1500:0 - 9000 m
    • Symmetra PX 64kW Scalable to 96kW:0 - 999.9 m
  • Width
    • Power Saving Back-UPS RS 1500:112 mm
    • Symmetra PX 64kW Scalable to 96kW:1200 mm
  • Depth
    • Power Saving Back-UPS RS 1500:380 mm
    • Symmetra PX 64kW Scalable to 96kW:1070 mm
  • Height
    • Power Saving Back-UPS RS 1500:301 mm
    • Symmetra PX 64kW Scalable to 96kW:1991 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of BR1500G-FR, SY64K96H-PD
42 specifications
Features2 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers1.5 kVA64 kVA
Output powerDiffers865 W64000 W
Surge energy ratingKnown for one445 JUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source0.02%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source0.05%
Noise levelKnown for oneUnknown — not stated by the source63 dB
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneType E / FUnknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
SmartSlotKnown for oneNoUnknown — not stated by the source
SmartConnect portKnown for oneNoUnknown — not stated by the source
Battery1 differ
Battery recharge timeDiffers8 h3.50 h
Replacement battery cartridgeKnown for one1Unknown — not stated by the source
Designidentical
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Operational conditions2 differ
Storage temperature (T-T)Differs-15 - 45 °C-15 - 40 °C
Operating altitudeDiffers0 - 9000 m0 - 999.9 m
Packaging contentidentical
Management card includedKnown for oneNoUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers112 mm1200 mm
DepthDiffers380 mm1070 mm
HeightDiffers301 mm1991 mm
WeightDiffers11.6 kg1454 kg
Packaging dataidentical
Package weightKnown for one13.2 kgUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other features4 differ
Battery typeDiffersAPCRBC124VRLA
InterfaceDiffersUSBSmartSlot
Input connection typeDiffersIEC-320 C143PH + N + G
Filtering descriptionKnown for oneUL 1449Unknown — not stated by the source
Nominal input voltageDiffers230 V400 V
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Operating temperature (T-T)Known for one32 - 104 °FUnknown — not stated by the source
Package dimensions (WxDxH)Known for one238 x 488 x 387 mmUnknown — not stated by the source
Output connectionsKnown for oneUnknown — not stated by the source1x 3PH + N + G
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceEN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC 15 A,VFI-SS-111

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.