APC BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA vs Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 20specifications compared
  • 15differ
  • 5identical
  • 50known for one product only

Key differences

The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 1.65 kVA more output power capacity than the APC BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA (3 kVA vs 1.35 kVA). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 2,190 W more output power than the APC BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA (3000 W vs 810 W). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 132 V more input operation voltage (min) than the APC BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA (220 V vs 88 V). UPS topology: Line-Interactive on the APC BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA, Double-conversion (Online) on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA. Input frequency: 60 Hz on the APC BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA, 50/60 Hz on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA.

  • UPS topology
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:Line-Interactive
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
  • Output power capacity
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:1.35 kVA
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:810 W
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
  • Input operation voltage (min)
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:88 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:220 V
  • Input operation voltage (max)
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:147 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
  • Input frequency
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:60 Hz
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:50/60 Hz
  • AC outlet types
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:NEMA 5-15R
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:C19 coupler, C13 coupler
  • AC outlets quantity
    • BR1350MS uninterruptible power supply (UPS) Line-Interactive 1.35 kVA:10 AC outlet(s)
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:7 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of BR1350MS, Keor-DK-3000-B
70 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.35 kVA3 kVA
Output powerDiffers810 W3000 W
WaveformSineSine
Input operation voltage (min)Differs88 V220 V
Input operation voltage (max)Differs147 V240 V
Input frequencyDiffers60 Hz50/60 Hz
Output frequencyKnown for one60 HzUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one12 AUnknown — not stated by the source
Surge energy ratingKnown for one1080 JUnknown — not stated by the source
Hold time (max)Known for one10 msUnknown — not stated by the source
Hold time (min)Known for one8 msUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Surge protectionYesYes
Surge protection featuresKnown for oneCoax, NetworkUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneLow battery alarm, Overload alarmUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source98%
Efficiency (On-line mode)Known for oneUnknown — not stated by the source96%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98.3%
Power factorKnown for oneUnknown — not stated by the source1
Output power factorKnown for oneUnknown — not stated by the source1
Crest factorKnown for oneUnknown — not stated by the source3:1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5-15RC19 coupler, C13 coupler
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityDiffers10 AC outlet(s)7 AC outlet(s)
USB portYesYes
Network card slotKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery recharge timeDiffers16 h4 h
Hot-swap batteryYesYes
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries includedKnown for oneUnknown — not stated by the source6 pc(s)
Number of battery cellsKnown for oneUnknown — not stated by the source6
Design2 differ
Form factorDiffersTowerRackmount/Tower
Product colourDiffersBlackBlack, White
Cable lengthKnown for one1.8 mUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Rack capacityKnown for oneUnknown — not stated by the source2U
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneUSB cableUnknown — not stated by the source
ManualYesYes
Quick installation guideKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneFCC 15 B, NOM, TUV C-USUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers100 mm440 mm
DepthDiffers368 mm640 mm
HeightDiffers260 mm88 mm
WeightDiffers11.7 kg2.7 kg
Packaging dataidentical
Package widthKnown for one223 mmUnknown — not stated by the source
Package depthKnown for one482 mmUnknown — not stated by the source
Package heightKnown for one358 mmUnknown — not stated by the source
Package weightKnown for one13.3 kgUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for one16 pc(s)Unknown — not stated by the source
Master (outer) case gross weightKnown for one13.3 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one1 pc(s)Unknown — not stated by the source
Other featuresidentical
Output voltageKnown for one120 VUnknown — not stated by the source