Key differences

  • UPS topology
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:Standby (Offline)
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Double-conversion (Online)
  • Output power capacity
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:0.125 kVA
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6 kVA
  • Output power
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:75 W
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:5400 W
  • Waveform
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:Square
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Sine
  • Input operation voltage (min)
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:90 V
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:110 V
  • Input operation voltage (max)
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:140 V
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:276 V
  • Surge energy rating
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:120 J
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:445 J
  • Noise level
    • BGE90M-CA uninterruptible power supply (UPS) Standby (Offline) 0.125 kVA:45 dB
    • OLS6000ERT6UM uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:60 dB

Side by side

Differences highlightedShow differences only (off)
Comparison of BGE90M-CA, OLS6000ERT6UM
77 specifications
Features9 differ
UPS topologyDiffersStandby (Offline)Double-conversion (Online)
Output power capacityDiffers0.125 kVA6 kVA
Output powerDiffers75 W5400 W
WaveformDiffersSquareSine
Input operation voltage (min)Differs90 V110 V
Input operation voltage (max)Differs140 V276 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source208 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Maximum currentKnown for oneUnknown — not stated by the source27.3 A
Surge energy ratingDiffers120 J445 J
Efficiency (On-line mode)Known for oneUnknown — not stated by the source96%
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Power Factor Correction (PFC) typeKnown for oneUnknown — not stated by the sourceActive
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Overload capacity (10 minutes)Known for oneUnknown — not stated by the source125%
Overload capacity (1 minute)Known for oneUnknown — not stated by the source150%
Overload capacity - battery mode (1 minute)Known for oneUnknown — not stated by the source150%
Total Harmonic Distortion (THD) (linear load)Known for oneUnknown — not stated by the source2%
Total Harmonic Distortion (THD) (non-linear load)Known for oneUnknown — not stated by the source5%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Noise levelDiffers45 dB60 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceInput fuse, Over current, Short circuit
Audible alarm(s)YesYes
Audible alarm modesDiffersLow battery alarm, Overload alarmAlarm when on battery, Fault, Low battery alarm, Overload alarm
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Hold time (max)Known for one10 msUnknown — not stated by the source
Hold time (min)Known for one8 msUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesKnown for oneUnknown — not stated by the sourceTerminal
Power plugDiffersNEMA 1-15PTerminal
AC outlets quantityDiffers3 AC outlet(s)1 AC outlet(s)
USB portYesYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
Parallel ports quantityKnown for oneUnknown — not stated by the source4
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
USB 2.0 ports quantityKnown for one2Unknown — not stated by the source
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source6 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source16.4 min
Battery recharge timeDiffers6 h7 h
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Design3 differ
Form factorDiffersTowerRackmount/Tower
Product colourDiffersWhiteBlack
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Rack capacityKnown for oneUnknown — not stated by the source3U
Display typeDiffersLEDLCD
Cable lengthKnown for one1.52 mUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 900 m0 - 1000 m
Non-operating altitudeDiffers0 - 4500 m0 - 50000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneInput power cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersCEC, FCC 15 B, NOM, TUV-NURTL, REACHCE
Weight & dimensions4 differ
WidthDiffers105 mm438 mm
DepthDiffers225 mm680 mm
HeightDiffers132 mm130.5 mm
WeightDiffers3 kg17.5 kg
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceBPSE240V75ART3U
Output voltageKnown for one120 VUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one164 mmUnknown — not stated by the source
Package depthKnown for one299 mmUnknown — not stated by the source
Package heightKnown for one204 mmUnknown — not stated by the source
Package weightKnown for one3.3 kgUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for one72 pc(s)Unknown — not stated by the source
Master (outer) case gross weightKnown for one7 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one2 pc(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.