Product comparison · 2 uninterruptible power supplies (upss)

APC BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA vs APC METERED RACK-MOUNT PDU

Add a product
  • 7specifications compared
  • 6differ
  • 1identical
  • 50known for one product only

Key differences

  • Product colour
    • BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA:Black
    • METERED RACK-MOUNT PDU:Beige
  • Cable length
    • BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA:1.52 m
    • METERED RACK-MOUNT PDU:3.05 m
  • Operating temperature (T-T)
    • BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA:0 - 40 °C
    • METERED RACK-MOUNT PDU:0 - 45 °C
  • Storage temperature (T-T)
    • BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA:-15 - 45 °C
    • METERED RACK-MOUNT PDU:-25 - 65 °C
  • Operating relative humidity (H-H)
    • BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA:10 - 90%
    • METERED RACK-MOUNT PDU:0 - 95%
  • Operating altitude
    • BE850M2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA:0 - 3000 m
    • METERED RACK-MOUNT PDU:0 - 15000 m

Side by side

Differences highlightedShow differences only (on)
Comparison of BE850M2, METERED RACK-MOUNT PDU
57 specifications
Featuresidentical
UPS topologyKnown for oneStandby (Offline)Unknown — not stated by the source
Output power capacityKnown for one0.85 kVAUnknown — not stated by the source
Output powerKnown for one450 WUnknown — not stated by the source
Input operation voltage (min)Known for one92 VUnknown — not stated by the source
Input operation voltage (max)Known for one139 VUnknown — not stated by the source
Input frequencyKnown for one50/60 HzUnknown — not stated by the source
Output operation voltage (min)Known for one120 VUnknown — not stated by the source
Output operation voltage (max)Known for one120 VUnknown — not stated by the source
Output frequency regulationKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentKnown for one5 AUnknown — not stated by the source
Surge energy ratingKnown for one354 JUnknown — not stated by the source
Hold time (max)Known for one10 msUnknown — not stated by the source
Hold time (min)Known for one6 msUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarm, Overload alarmUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneNEMA 5–15RUnknown — not stated by the source
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityKnown for one9 AC outlet(s)Unknown — not stated by the source
Number of type F outputsKnown for one0Unknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
USB 2.0 ports quantityKnown for one2Unknown — not stated by the source
Batteryidentical
Battery capacityKnown for one84 VAhUnknown — not stated by the source
Number of batteries supportedKnown for one1Unknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorKnown for oneCompactUnknown — not stated by the source
Product colourDiffersBlackBeige
Cable lengthDiffers1.52 m3.05 m
LED indicatorsKnown for oneYesUnknown — not stated by the source
CompatibilityKnown for oneUnknown — not stated by the sourceInfraStruXure Rack-mount PDU
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 45 °C
Storage temperature (T-T)Differs-15 - 45 °C-25 - 65 °C
Operating relative humidity (H-H)Differs10 - 90%0 - 95%
Operating altitudeDiffers0 - 3000 m0 - 15000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneUSB cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one327 mmUnknown — not stated by the source
DepthKnown for one105 mmUnknown — not stated by the source
HeightKnown for one139 mmUnknown — not stated by the source
WeightKnown for one4.1 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one416 mmUnknown — not stated by the source
Package depthKnown for one168 mmUnknown — not stated by the source
Package heightKnown for one196 mmUnknown — not stated by the source
Package weightKnown for one4.4 kgUnknown — not stated by the source
Other featuresidentical
Output connectionsKnown for oneUnknown — not stated by the source(21) IEC 320 C13 (4)IEC 320 C19
Input connection typeKnown for oneUnknown — not stated by the sourceIEC-320 C20
Dimensions (WxDxH)Known for oneUnknown — not stated by the source88.9 x 44.5 x 1219.2 mm
Nominal input voltageKnown for oneUnknown — not stated by the source230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Output voltage noteKnown for oneUnknown — not stated by the sourceMaximum Total Current Draw per Phase - 16 A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons