Product comparison · 2 uninterruptible power supplies (upss)

APC BE350G uninterruptible power supply (UPS) 0.35 kVA vs APC Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution

Add a product
  • 15specifications compared
  • 13differ
  • 2identical
  • 8known for one product only

Key differences

  • Output power capacity
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:0.35 kVA
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:100 kVA
  • Output power
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:200 W
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:100000 W
  • Input frequency
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:60 Hz
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:40/70 Hz
  • Battery recharge time
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:16 h
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:3.50 h
  • Storage temperature (T-T)
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:-15 - 45 °C
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:-15 - 40 °C
  • Operating relative humidity (H-H)
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:5 - 95%
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:0 - 95%
  • Storage relative humidity (H-H)
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:5 - 95%
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:0 - 95%
  • Weight
    • BE350G uninterruptible power supply (UPS) 0.35 kVA:3.64 kg
    • Symmetra PX 100kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution:2632.7 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of BE350G, SY100K250DR-PD
23 specifications
Features3 differ
Output power capacityDiffers0.35 kVA100 kVA
Output powerDiffers200 W100000 W
Input frequencyDiffers60 Hz40/70 Hz
Surge energy ratingKnown for one365 JUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery recharge timeDiffers16 h3.50 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Designidentical
Cable lengthKnown for one1.52 mUnknown — not stated by the source
Operational conditions3 differ
Storage temperature (T-T)Differs-15 - 45 °C-15 - 40 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Certificates1 differ
CertificationDiffersRoHScUL Listed,CE,EN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC Part 15 Class A,UL Listed,VFI-SS-111
Weight & dimensions1 differ
WeightDiffers3.64 kg2632.7 kg
Other features4 differ
Output connectionsDiffersNEMA 5-15R1x Hard Wire 4-wire (3PH + G) 1x Hard Wire 5-wire (3PH + N + G)
Input connection typeDiffersNEMA 5-15PHard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)
Dimensions (WxDxH)Differs159 x 279 x 89 mm2350 x 1070 x 1991 mm
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Package dimensions (WxDxH)Differs197 x 362 x 127 mm2990 x 1270 x 2150 mm
Battery typeKnown for oneUnknown — not stated by the sourceVRLA
InterfaceKnown for oneUnknown — not stated by the sourceSmart-Slot

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons