Product comparison · 2 uninterruptible power supplies (upss)

APC Back-UPS LS 700 vs Trust 550VA UPS PW-4055T

Add a product
  • 5specifications compared
  • 5differ
  • 0identical
  • 26known for one product only

Key differences

The APC Back-UPS LS 700 has 0.15 kVA more output power capacity than the Trust 550VA UPS PW-4055T (0.7 kVA vs 0.55 kVA). The Trust 550VA UPS PW-4055T has 17.8 min more typical backup time at full load than the APC Back-UPS LS 700 (20 min vs 2.2 min). The APC Back-UPS LS 700 has 3.37 kg more weight than the Trust 550VA UPS PW-4055T (7.73 kg vs 4.36 kg). Package dimensions (WxDxH): 213 x 328 x 290 mm on the APC Back-UPS LS 700, 385 x 140 x 225 mm on the Trust 550VA UPS PW-4055T.

  • Output power capacity
    • Back-UPS LS 700:0.7 kVA
    • 550VA UPS PW-4055T:0.55 kVA
  • Typical backup time at full load
    • Back-UPS LS 700:2.2 min
    • 550VA UPS PW-4055T:20 min
  • Weight
    • Back-UPS LS 700:7.73 kg
    • 550VA UPS PW-4055T:4.36 kg
  • Package weight
    • Back-UPS LS 700:8.64 kg
    • 550VA UPS PW-4055T:4.7 kg
  • Package dimensions (WxDxH)
    • Back-UPS LS 700:213 x 328 x 290 mm
    • 550VA UPS PW-4055T:385 x 140 x 225 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Back-UPS LS 700, 550VA UPS PW-4055T
31 specifications
Features1 differ
Output power capacityDiffers0.7 kVA0.55 kVA
Output powerKnown for one410 WUnknown — not stated by the source
Input frequencyKnown for one50/60 HzUnknown — not stated by the source
Surge energy ratingKnown for one510 JUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Battery1 differ
Typical backup time at full loadDiffers2.2 min20 min
Typical backup time at half loadKnown for one11.1 minUnknown — not stated by the source
Battery recharge timeKnown for one10 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Designidentical
Cable lengthKnown for one1.8 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Product colourKnown for oneUnknown — not stated by the sourceBlack
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL/FCC/CE/C-TickUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneCSA/FCC Part 68/UL 1778Unknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers7.73 kg4.36 kg
Packaging data1 differ
Package weightDiffers8.64 kg4.7 kg
Other features1 differ
Output connectionsKnown for one7 x NEMA 5-15RUnknown — not stated by the source
Input connection typeKnown for oneNEMA 5-15PUnknown — not stated by the source
Dimensions (WxDxH)Known for one127 x 201 x 239 mmUnknown — not stated by the source
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Operating temperature (T-T)Known for one0 - 40 °FUnknown — not stated by the source
Package dimensions (WxDxH)Differs213 x 328 x 290 mm385 x 140 x 225 mm
Non-operating relative humidity (non-condensing)Known for one0 - 95%Unknown — not stated by the source
Weight (imperial)Known for one7.71 kg (17 lbs)Unknown — not stated by the source
Minimum system requirementsKnown for oneUnknown — not stated by the sourceWall power connection.