Product comparison · 2 uninterruptible power supplies (upss)

APC Back-UPS ES 700VA vs APC BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA

Add a product
  • 19specifications compared
  • 15differ
  • 4identical
  • 29known for one product only

Key differences

The APC Back-UPS ES 700VA has 0.2 kVA more output power capacity than the APC BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA (0.7 kVA vs 0.5 kVA). The APC Back-UPS ES 700VA has 105 W more output power than the APC BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA (405 W vs 300 W). The APC BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA has 170 J more surge energy rating than the APC Back-UPS ES 700VA (480 J vs 310 J). Storage temperature (T-T): 0 - 40 °C on the APC Back-UPS ES 700VA, -15 - 45 °C on the APC BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA. Operating altitude: 0 - 15000 m on the APC Back-UPS ES 700VA, 0 - 3000 m on the APC BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA.

  • Output power capacity
    • Back-UPS ES 700VA:0.7 kVA
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:0.5 kVA
  • Output power
    • Back-UPS ES 700VA:405 W
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:300 W
  • Surge energy rating
    • Back-UPS ES 700VA:310 J
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:480 J
  • Cable length
    • Back-UPS ES 700VA:1.83 m
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:1.8 m
  • Storage temperature (T-T)
    • Back-UPS ES 700VA:0 - 40 °C
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:-15 - 45 °C
  • Operating relative humidity (H-H)
    • Back-UPS ES 700VA:0 - 95%
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:5 - 95%
  • Storage relative humidity (H-H)
    • Back-UPS ES 700VA:0 - 95%
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:5 - 95%
  • Operating altitude
    • Back-UPS ES 700VA:0 - 15000 m
    • BK500BLK uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:0 - 3000 m

Side by side

Differences highlightedShow differences only (on)
Comparison of Back-UPS ES 700VA, BK500BLK
48 specifications
Features3 differ
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output power capacityDiffers0.7 kVA0.5 kVA
Output powerDiffers405 W300 W
WaveformKnown for oneUnknown — not stated by the sourceSine
Input operation voltage (min)Known for oneUnknown — not stated by the source98 V
Input operation voltage (max)Known for oneUnknown — not stated by the source140 V
Input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Surge energy ratingDiffers310 J480 J
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Low battery alarm, Overload alarm
Maximum currentKnown for one10 AUnknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Ports & interfacesidentical
USB portKnown for oneUnknown — not stated by the sourceYes
Batteryidentical
Battery technologyKnown for oneUnknown — not stated by the sourceLead-Acid
Typical backup time at full loadKnown for oneUnknown — not stated by the source2.4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13.9 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorKnown for oneUnknown — not stated by the sourceTower
Cable lengthDiffers1.83 m1.8 m
Operational conditions4 differ
Storage temperature (T-T)Differs0 - 40 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Operating altitudeDiffers0 - 15000 m0 - 3000 m
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL,/FCC/CE/C-Tick
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceFCC Part 15 Class B/Industry Canada/UL 1778/cUL
Weight & dimensions1 differ
WidthKnown for oneUnknown — not stated by the source91 mm
DepthKnown for oneUnknown — not stated by the source284 mm
HeightKnown for oneUnknown — not stated by the source165 mm
WeightDiffers6.8 kg6.27 kg
Packaging data1 differ
Package weightDiffers15 kg6.95 kg
Logistics data1 differ
Products per palletDiffers72 pc(s)80 pc(s)
Other features4 differ
Output connectionsKnown for oneUnknown — not stated by the source6 x NEMA 5-15R
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA 5-15P
Dimensions (WxDxH)Differs230 x 285 x 86 mm91 x 284 x 165 mm
Nominal input voltageDiffers230 V120 V
Nominal output voltageDiffers230 V120 V
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °F
Package dimensions (WxDxH)Differs380 x 272 x 328 mm175 x 357 x 263 mm
Non-operating relative humidity (non-condensing)Known for oneUnknown — not stated by the source0 - 95%
Weight (imperial)Known for oneUnknown — not stated by the source6.26 kg (13.8 lbs)
Battery typeKnown for one1x RBC17Unknown — not stated by the source
Filtering descriptionKnown for one5% IEEE/UL 1449Unknown — not stated by the source
Networking featuresKnown for oneDSL/10-100 Base-T RJ-45Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.