Product comparison · 2 uninterruptible power supplies (upss)

APC Back-UPS 325, UK vs APC Silcon 120kW 400V UPS

Add a product
  • 6specifications compared
  • 4differ
  • 2identical
  • 24known for one product only

Key differences

  • Output power capacity
    • Back-UPS 325, UK:0.325 kVA
    • Silcon 120kW 400V UPS:120 kVA
  • Output power
    • Back-UPS 325, UK:185 W
    • Silcon 120kW 400V UPS:120000 W
  • Storage temperature (T-T)
    • Back-UPS 325, UK:-15 - 45 °C
    • Silcon 120kW 400V UPS:-50 - 40 °C
  • Weight
    • Back-UPS 325, UK:4 kg
    • Silcon 120kW 400V UPS:800 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of Back-UPS 325, UK, Silcon 120kW 400V UPS
30 specifications
Features2 differ
Output power capacityDiffers0.325 kVA120 kVA
Output powerDiffers185 W120000 W
Input operation voltage (min)Known for one230 VUnknown — not stated by the source
Input operation voltage (max)Known for one230 VUnknown — not stated by the source
Output operation voltage (min)Known for one230 VUnknown — not stated by the source
Output operation voltage (max)Known for one230 VUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneBS 1363Unknown — not stated by the source
AC outlets quantityKnown for one4 AC outlet(s)Unknown — not stated by the source
Designidentical
Form factorKnown for oneCompactUnknown — not stated by the source
Product colourKnown for oneCharcoalUnknown — not stated by the source
CompatibilityKnown for oneCE, EN 50091-1, EN 50091-2Unknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 45 °C-50 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Weight & dimensions1 differ
WidthKnown for one360 mmUnknown — not stated by the source
DepthKnown for one95 mmUnknown — not stated by the source
HeightKnown for one115 mmUnknown — not stated by the source
WeightDiffers4 kg800 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
InterfaceKnown for oneUnknown — not stated by the sourceDB-25 RS-232
Output connectionsKnown for oneUnknown — not stated by the source- 3PH - 3PH + G - 3PH + N - 3PH - PEN - 3PH + N + G
Input connection typeKnown for oneUnknown — not stated by the source3PH + N + G, 3PH + PEN, 3PH + N
Dimensions (WxDxH)Known for oneUnknown — not stated by the source1125 x 800 x 1800 mm
Nominal input voltageKnown for oneUnknown — not stated by the source400 V
Nominal output voltageKnown for oneUnknown — not stated by the source400 V
Output voltage noteKnown for oneUnknown — not stated by the source380: 400 or 415