Product comparison · 2 uninterruptible power supplies (upss)

APC 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA vs CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA

Add a product
  • 13specifications compared
  • 9differ
  • 4identical
  • 22known for one product only

Key differences

The CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA has 2 kVA more output power capacity than the APC 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA (3 kVA vs 1 kVA). The CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA has 1,580 W more output power than the APC 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA (2250 W vs 670 W). The CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA has 1,554 J more surge energy rating than the APC 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA (1874 J vs 320 J). Input frequency: 60 Hz on the APC 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA, 50/60 Hz on the CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA. Replacement battery cartridge: RBC6 on the APC 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA, BB - HR9-12 on the CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA.

  • Output power capacity
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:1 kVA
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 kVA
  • Output power
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:670 W
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:2250 W
  • Input frequency
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:60 Hz
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:50/60 Hz
  • Surge energy rating
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:320 J
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:1874 J
  • Response time
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:1449 ms
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:4 ms
  • Replacement battery cartridge
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:RBC6
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:BB - HR9-12
  • Weight
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:19.4 kg
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:37.2 kg
  • Dimensions (WxDxH)
    • 19061CL-3F-1E uninterruptible power supply (UPS) 1 kVA:170 x 439 x 216 mm
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:438.15 x 495.3 x 89 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of 19061CL-3F-1E, PR3000LCDRT2U
35 specifications
Features5 differ
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output power capacityDiffers1 kVA3 kVA
Output powerDiffers670 W2250 W
Input frequencyDiffers60 Hz50/60 Hz
Surge energy ratingDiffers320 J1874 J
Response timeDiffers1449 ms4 ms
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)YesYes
Ports & interfacesidentical
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) ports11
Battery1 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Typical backup time at full loadKnown for oneUnknown — not stated by the source3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source8 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeDiffersRBC6BB - HR9-12
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL1778, cUL 107.1, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers19.4 kg37.2 kg
Other features2 differ
Output connectionsKnown for oneUnknown — not stated by the sourceNEMA 5-20R, NEMA L5-30R
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA L5-30P
Dimensions (WxDxH)Differs170 x 439 x 216 mm438.15 x 495.3 x 89 mm
Operating temperature (T-T)Differs0 - 40 °F32 - 95 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 495.3 x 88.9 mm (17.2 x 19.5 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source37.2 kg (82 lbs)
Battery typeKnown for oneLead-AcidUnknown — not stated by the source
InterfaceKnown for oneDB-9 RS-232Unknown — not stated by the source
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Designidentical
Product colourKnown for oneBeigeUnknown — not stated by the source
Cable lengthKnown for one1.83 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.