  • Output power capacity
    • Protect D. 10000:10 kVA
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:1.5 kVA
  • Output power
    • Protect D. 10000:9000 W
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:900 W
  • Input frequency
    • Protect D. 10000:50/60 Hz
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:47/63 Hz
  • AC outlet types
    • Protect D. 10000:C19 coupler, Terminal
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:NEMA 5–15R
  • AC outlets quantity
    • Protect D. 10000:4 AC outlet(s)
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:8 AC outlet(s)
  • RS-232 ports
    • Protect D. 10000:1
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:2
  • Battery recharge time
    • Protect D. 10000:3 h
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:8 h
  • Form factor
    • Protect D. 10000:Rackmount
    • OR1500LCDRM2 uninterruptible power supply (UPS) 1.5 kVA:Rackmount/Tower

Side by side

Differences highlightedShow differences only (off)
Comparison of Protect D. 10000, OR1500LCDRM2
57 specifications
Features3 differ
Output power capacityDiffers10 kVA1.5 kVA
Output powerDiffers9000 W900 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Known for one176 VUnknown — not stated by the source
Input operation voltage (max)Known for one276 VUnknown — not stated by the source
Input frequencyDiffers50/60 Hz47/63 Hz
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Maximum currentKnown for one47 AUnknown — not stated by the source
EfficiencyKnown for one97%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm(s)YesYes
Surge energy ratingKnown for oneUnknown — not stated by the source1840 J
Hold time (max)Known for oneUnknown — not stated by the source3 ms
Response timeKnown for oneUnknown — not stated by the source4 ms
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceCoax
Ports & interfaces3 differ
AC outlet typesDiffersC19 coupler, TerminalNEMA 5–15R
Power plugKnown for oneTerminalUnknown — not stated by the source
AC outlets quantityDiffers4 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantity11
RS-232 portsDiffers12
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery voltageKnown for one240 VUnknown — not stated by the source
Battery recharge timeDiffers3 h8 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Typical backup time at full loadKnown for oneUnknown — not stated by the source6 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source18 min
Design3 differ
Form factorDiffersRackmountRackmount/Tower
Product colourDiffersGreyBlack
Housing materialKnown for oneMetalUnknown — not stated by the source
Rack capacityDiffers5U2U
Display typeLCDLCD
LED indicatorsYesYes
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 35 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeKnown for one0 - 1000 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersEN62010-2 EN62040-1UL1778, cUL 107.1, FCC DOC Class B
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions1 differ
WidthKnown for one486 mmUnknown — not stated by the source
DepthKnown for one715 mmUnknown — not stated by the source
HeightKnown for one220 mmUnknown — not stated by the source
WeightDiffers82.5 kg23.6 kg
Other featuresidentical
Output connectionsKnown for oneUnknown — not stated by the sourceNEMA 5-15R
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA 5-15P
Dimensions (WxDxH)Known for oneUnknown — not stated by the source438.15 x 400 x 89 mm
Nominal input voltageKnown for oneUnknown — not stated by the source90-140 V
Operating temperature (T-T)Known for oneUnknown — not stated by the source-4 - 115 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source23.6 kg (52 lbs)