Product comparison · 2 uninterruptible power supplies (upss)

AEG Protect C. R. vs APC MGE Galaxy 3500 15kVA 400V

Add a product
  • 10specifications compared
  • 8differ
  • 2identical
  • 26known for one product only

Key differences

  • Output power capacity
    • Protect C. R.:1 kVA
    • MGE Galaxy 3500 15kVA 400V:15 kVA
  • Output power
    • Protect C. R.:700 W
    • MGE Galaxy 3500 15kVA 400V:12000 W
  • Maximum current
    • Protect C. R.:7 A
    • MGE Galaxy 3500 15kVA 400V:20 A
  • Emergency Power Off (EPO)
    • Protect C. R.:No
    • MGE Galaxy 3500 15kVA 400V:Yes
  • Noise level
    • Protect C. R.:45 dB
    • MGE Galaxy 3500 15kVA 400V:51.3 dB
  • Weight
    • Protect C. R.:16.5 kg
    • MGE Galaxy 3500 15kVA 400V:259 kg
  • Dimensions (WxDxH)
    • Protect C. R.:482.6 x 450 x 88 mm
    • MGE Galaxy 3500 15kVA 400V:523 x 838 x 1491 mm
  • Output voltage note
    • Protect C. R.:36 Vdc
    • MGE Galaxy 3500 15kVA 400V:+/- 5%

Side by side

Differences highlightedShow differences only (on)
Comparison of Protect C. R., MGE Galaxy 3500 15kVA 400V
36 specifications
Features5 differ
Output power capacityDiffers1 kVA15 kVA
Output powerDiffers700 W12000 W
Maximum currentDiffers7 A20 A
Emergency Power Off (EPO)DiffersNoYes
Noise levelDiffers45 dB51.3 dB
Input frequencyKnown for oneUnknown — not stated by the source40/70 Hz
Ports & interfacesidentical
Number of output IEC jumpersKnown for one4Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Batteryidentical
Typical backup time at full loadKnown for one6 minUnknown — not stated by the source
Typical backup time at half loadKnown for one20 minUnknown — not stated by the source
Battery recharge timeKnown for one5 hUnknown — not stated by the source
Hot-swap batteryKnown for oneNoUnknown — not stated by the source
Designidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditionsidentical
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 999.9 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Weight & dimensions1 differ
WeightDiffers16.5 kg259 kg
Other features2 differ
InterfaceKnown for oneRS-232Unknown — not stated by the source
Dimensions (WxDxH)Differs482.6 x 450 x 88 mm523 x 838 x 1491 mm
Mac compatibilityKnown for oneYesUnknown — not stated by the source
Networking featuresKnown for one10/100 Mbit/sUnknown — not stated by the source
Output voltage noteDiffers36 Vdc+/- 5%
Size (imperial)Known for one48.3 cm (19")Unknown — not stated by the source
Electrical output connectionsKnown for one4x IEC 320 C13Unknown — not stated by the source
Non-operating relative humidity (non-condensing)Known for one0 - 90%Unknown — not stated by the source
Output connectionsKnown for oneUnknown — not stated by the source1 x 4-wire (3PH + G) 1 x 5-wire (3PH + N + G) 1 x Screw Terminals
Input connection typeKnown for oneUnknown — not stated by the source5-wire (3PH + N + G)
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source650 x 1062 x 1643 mm
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCE,EN 50091-2,EN/IEC 62040-3,EN/IEC 62040-1-1,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-111
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source290 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons