Product comparison · 2 uninterruptible power supplies (upss)

AEG Protect B. 1800 PRO BP vs CyberPower DL850ELCD uninterruptible power supply (UPS) 0.85 kVA

Add a product
  • 17specifications compared
  • 12differ
  • 5identical
  • 27known for one product only

Key differences

  • Output power capacity
    • Protect B. 1800 PRO BP:1.8 kVA
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:0.85 kVA
  • Output power
    • Protect B. 1800 PRO BP:1620 W
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:490 W
  • Input frequency
    • Protect B. 1800 PRO BP:50/60 Hz
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:47/63 Hz
  • AC outlet types
    • Protect B. 1800 PRO BP:C13 coupler
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:Type F
  • AC outlets quantity
    • Protect B. 1800 PRO BP:8 AC outlet(s)
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:3 AC outlet(s)
  • Typical backup time at full load
    • Protect B. 1800 PRO BP:17.5 min
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:2 min
  • Typical backup time at half load
    • Protect B. 1800 PRO BP:43.5 min
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:7 min
  • Product colour
    • Protect B. 1800 PRO BP:Black, Silver
    • DL850ELCD uninterruptible power supply (UPS) 0.85 kVA:Black

Side by side

Differences highlightedShow differences only (on)
Comparison of Protect B. 1800 PRO BP, DL850ELCD
44 specifications
Features3 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers1.8 kVA0.85 kVA
Output powerDiffers1620 W490 W
Input operation voltage (min)Known for one220 VUnknown — not stated by the source
Input operation voltage (max)Known for one240 VUnknown — not stated by the source
Input frequencyDiffers50/60 Hz47/63 Hz
Output operation voltage (min)Known for one208 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentKnown for one9.7 AUnknown — not stated by the source
EfficiencyKnown for one97%Unknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
WaveformKnown for oneUnknown — not stated by the sourceSine
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersC13 couplerType F
AC outlets quantityDiffers8 AC outlet(s)3 AC outlet(s)
RS-232 portsKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery2 differ
Typical backup time at full loadDiffers17.5 min2 min
Typical backup time at half loadDiffers43.5 min7 min
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Design1 differ
Form factorKnown for oneRackmount/TowerUnknown — not stated by the source
Product colourDiffersBlack, SilverBlack
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers482.6 mm90 mm
DepthDiffers520 mm190 mm
HeightDiffers88 mm235 mm
WeightDiffers26.5 kg3.1 kg
Other featuresidentical
Number of phasesKnown for one1Unknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Packaging dataidentical
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.