Product comparison · 2 split-system air conditioners

LG D09RN.UL2 air conditioner Air conditioner outdoor unit White vs LG New Standard Plus

Add a product
  • 15specifications compared
  • 10differ
  • 5identical
  • 38known for one product only

Key differences

  • Type
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:Air conditioner outdoor unit
    • New Standard Plus:Air conditioner indoor unit
  • Seasonal efficiency rating (cooling) (SEER)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:7.7
    • New Standard Plus:6.5
  • Seasonal efficiency rating (heating) (SCOP) (Average heating season)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:4.6
    • New Standard Plus:4
  • Cooling energy efficiency (EER, W/W)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:4.5
    • New Standard Plus:3.73
  • Heating energy efficiency (COP, W/W)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:4.5
    • New Standard Plus:3.81
  • Energy efficiency class (heating) (Average heating season)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:A++
    • New Standard Plus:A+
  • Annual energy consumption (cooling)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:114 kWh
    • New Standard Plus:134 kWh
  • Annual energy consumption (heating) (Average heating season)
    • D09RN.UL2 air conditioner Air conditioner outdoor unit White:853 kWh
    • New Standard Plus:840 kWh

Side by side

Differences highlightedShow differences only (on)
Comparison of D09RN.UL2, New Standard Plus
53 specifications
Features6 differ
TypeDiffersAir conditioner outdoor unitAir conditioner indoor unit
Air conditioner functionsDiffersCooling, Dehumidifying, HeatingCooling, Dehumidifying, Fan, Heating
Suitable for room area up toKnown for oneUnknown — not stated by the source25 m²
Seasonal efficiency rating (cooling) (SEER)Differs7.76.5
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Differs4.64
Cooling energy efficiency (EER, W/W)Differs4.53.73
Heating energy efficiency (COP, W/W)Differs4.53.81
Cooling capacity in watts (nominal)Known for oneUnknown — not stated by the source2500 W
Cooling capacity in watts (min)Known for oneUnknown — not stated by the source890 W
Cooling capacity in watts (max)Known for oneUnknown — not stated by the source3700 W
Heating capacity in watts (nominal) (Average heating season)Known for oneUnknown — not stated by the source3200 W
Heating capacity in watts (min)Known for oneUnknown — not stated by the source890 W
Heating capacity in watts (max)Known for oneUnknown — not stated by the source4100 W
Dehumidifying capacityKnown for oneUnknown — not stated by the source1.1 l/h
Multi-splitKnown for oneNoUnknown — not stated by the source
IonizerKnown for oneYesUnknown — not stated by the source
Refrigerating mediumKnown for oneR410AUnknown — not stated by the source
Refrigerating medium weightKnown for one1 kgUnknown — not stated by the source
Compressor typeKnown for oneRotaryUnknown — not stated by the source
Gas hose diameterKnown for one9.52 mmUnknown — not stated by the source
Liquid hose diameterKnown for one6.35 mmUnknown — not stated by the source
Operating temperature (cooling) (T-T)Known for one-15 - 48 °CUnknown — not stated by the source
Operating temperature (heating) (T-T)Known for one-15 - 24 °CUnknown — not stated by the source
Power4 differ
Energy efficiency class (heating) (Average heating season)DiffersA++A+
Annual energy consumption (cooling)Differs114 kWh134 kWh
Annual energy consumption (heating) (Average heating season)Differs853 kWh840 kWh
CurrentDiffers16 A15 A
Design load (cooling)Known for oneUnknown — not stated by the source2.5 kW
Design load (heating) (Average heating season)Known for oneUnknown — not stated by the source3.2 kW
Networkidentical
Wi-FiKnown for oneUnknown — not stated by the sourceYes
Indoor unitidentical
Indoor unit typeKnown for oneUnknown — not stated by the sourceWall-mountable
Indoor unit noise level (high speed)Known for oneUnknown — not stated by the source59 dB
Cooling airflow (indoor unit)Known for oneUnknown — not stated by the source450 m³/h
Heating airflow (indoor unit)Known for oneUnknown — not stated by the source432 m³/h
Indoor unit widthKnown for oneUnknown — not stated by the source83.7 cm
Indoor unit depthKnown for oneUnknown — not stated by the source30.2 cm
Indoor unit heightKnown for oneUnknown — not stated by the source18.9 cm
Indoor unit weightKnown for oneUnknown — not stated by the source8.7 kg
Packaging contentidentical
Remote control includedKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Outdoor unitidentical
Outdoor unit noise levelKnown for one48 dBUnknown — not stated by the source
Outdoor unit sound power levelKnown for one65 dBUnknown — not stated by the source
Cooling airflow (outdoor unit)Known for one2100 m³/hUnknown — not stated by the source
Outdoor units quantityKnown for one1Unknown — not stated by the source
Outdoor unit widthKnown for one77 cmUnknown — not stated by the source
Outdoor unit depthKnown for one28.8 cmUnknown — not stated by the source
Outdoor unit heightKnown for one54.5 cmUnknown — not stated by the source
Outdoor unit weightKnown for one31 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.