Product comparison · 2 split-system air conditioners

Hotpoint KYRIS 30 MD0-O vs LG ARTCWHITE12.SET air conditioner Split system White

Add a product
  • 36specifications compared
  • 28differ
  • 8identical
  • 21known for one product only

Key differences

  • Type
    • KYRIS 30 MD0-O:Air conditioner outdoor unit
    • ARTCWHITE12.SET air conditioner Split system White:Split system
  • Seasonal efficiency rating (cooling) (SEER)
    • KYRIS 30 MD0-O:6.8
    • ARTCWHITE12.SET air conditioner Split system White:6.1
  • Cooling energy efficiency (EER, W/W)
    • KYRIS 30 MD0-O:3.74
    • ARTCWHITE12.SET air conditioner Split system White:3.98
  • Heating energy efficiency (COP, W/W)
    • KYRIS 30 MD0-O:3.8
    • ARTCWHITE12.SET air conditioner Split system White:4.17
  • Cooling capacity in watts (nominal)
    • KYRIS 30 MD0-O:1216 W
    • ARTCWHITE12.SET air conditioner Split system White:3500 W
  • Cooling capacity in watts (min)
    • KYRIS 30 MD0-O:751 W
    • ARTCWHITE12.SET air conditioner Split system White:900 W
  • Cooling capacity in watts (max)
    • KYRIS 30 MD0-O:3500 W
    • ARTCWHITE12.SET air conditioner Split system White:4040 W
  • Heating capacity in watts (nominal) (Average heating season)
    • KYRIS 30 MD0-O:830 W
    • ARTCWHITE12.SET air conditioner Split system White:4000 W

Side by side

Differences highlightedShow differences only (off)
Comparison of KYRIS 30 MD0-O, ARTCWHITE12.SET
57 specifications
Features16 differ
TypeDiffersAir conditioner outdoor unitSplit system
Product colourWhiteWhite
Air conditioner functionsDiffersCooling, HeatingCooling, Dehumidifying, Heating
Inverter technologyYesYes
IonizerKnown for oneUnknown — not stated by the sourceYes
Seasonal efficiency rating (cooling) (SEER)Differs6.86.1
Seasonal efficiency rating (heating) (SCOP) (Average heating season)44
Cooling energy efficiency (EER, W/W)Differs3.743.98
Heating energy efficiency (COP, W/W)Differs3.84.17
Cooling capacity in watts (nominal)Differs1216 W3500 W
Cooling capacity in watts (min)Differs751 W900 W
Cooling capacity in watts (max)Differs3500 W4040 W
Heating capacity in watts (nominal) (Average heating season)Differs830 W4000 W
Heating capacity in watts (min)Differs809 W890 W
Heating capacity in watts (max)Differs3700 W6000 W
Built-in displayKnown for oneUnknown — not stated by the sourceNo
Refrigerating mediumR410AR410A
Refrigerating medium weightDiffers1.1 kg1 kg
Compressor typeRotaryRotary
Hose length (max)Differs5 m20 m
Dehumidifying capacityDiffers1 l/h1.3 l/h
Remotely operatedKnown for oneUnknown — not stated by the sourceYes
Operating temperature (cooling) (T-T)Differs-15 - 50 °C-10 - 48 °C
Operating temperature (heating) (T-T)Differs-15 - 30 °C-15 - 24 °C
Multi-splitKnown for oneNoUnknown — not stated by the source
Cooling capacity (min)Known for one4151 BTU/hUnknown — not stated by the source
Cooling capacity (max)Known for one11949 BTU/hUnknown — not stated by the source
Heating capacity (min)Known for one2834 BTU/hUnknown — not stated by the source
Heating capacity (max)Known for one12632 BTU/hUnknown — not stated by the source
Hose diameterKnown for one9.66 mmUnknown — not stated by the source
Power6 differ
Energy efficiency class (heating) (Average heating season)A+A+
Annual energy consumption (cooling)Differs144 kWh201 kWh
Annual energy consumption (heating) (Average heating season)Differs1093 kWh1400 kWh
Power consumption (cooling) (max)Differs2810 W880 W
Power consumption (heating) (max)Differs3120 W960 W
AC input voltageDiffers230 V220-240 V
AC input frequencyDiffers50 - 60 Hz50 Hz
CurrentKnown for oneUnknown — not stated by the source15 A
Energy efficiency class (cooling) (legacy scale)A++A++
Power consumption (heating) (min)Known for one2720 WUnknown — not stated by the source
Indoor unitidentical
Indoor unit typeKnown for oneUnknown — not stated by the sourceWall-mountable
Indoor unit noise level (high speed)Known for oneUnknown — not stated by the source57 dB
Cooling airflow (indoor unit)Known for oneUnknown — not stated by the source720 m³/h
Heating airflow (indoor unit)Known for oneUnknown — not stated by the source630 m³/h
Indoor units quantityKnown for oneUnknown — not stated by the source1
Indoor unit widthKnown for oneUnknown — not stated by the source88.5 cm
Indoor unit depthKnown for oneUnknown — not stated by the source20.5 cm
Indoor unit heightKnown for oneUnknown — not stated by the source28.5 cm
Indoor unit weightKnown for oneUnknown — not stated by the source10 kg
Outdoor unit6 differ
Outdoor unit noise levelDiffers59 dB65 dB
Cooling airflow (outdoor unit)Differs2200 m³/h1980 m³/h
Heating airflow (outdoor unit)Known for oneUnknown — not stated by the source1980 m³/h
Outdoor units quantity11
Outdoor unit widthDiffers76 cm77 cm
Outdoor unit depthDiffers28.5 cm28.8 cm
Outdoor unit heightDiffers59 cm54.5 cm
Outdoor unit weightDiffers35 kg32.3 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.