Product comparison · 2 split-system air conditioners

Hotpoint ALYS 25 MC8-I vs LG A12LL UL2

Add a product
  • 27specifications compared
  • 19differ
  • 8identical
  • 26known for one product only

Key differences

  • Type
    • ALYS 25 MC8-I:Air conditioner indoor unit
    • A12LL UL2:Air conditioner outdoor unit
  • Seasonal efficiency rating (cooling) (SEER)
    • ALYS 25 MC8-I:5.88
    • A12LL UL2:6.2
  • Seasonal efficiency rating (heating) (SCOP) (Average heating season)
    • ALYS 25 MC8-I:4.63
    • A12LL UL2:3.8
  • Cooling capacity in watts (nominal)
    • ALYS 25 MC8-I:2758 W
    • A12LL UL2:3500 W
  • Cooling capacity in watts (min)
    • ALYS 25 MC8-I:1300 W
    • A12LL UL2:900 W
  • Cooling capacity in watts (max)
    • ALYS 25 MC8-I:3662 W
    • A12LL UL2:4000 W
  • Heating capacity in watts (nominal) (Average heating season)
    • ALYS 25 MC8-I:2809 W
    • A12LL UL2:4000 W
  • Heating capacity in watts (min)
    • ALYS 25 MC8-I:910 W
    • A12LL UL2:900 W

Side by side

Differences highlightedShow differences only (on)
Comparison of ALYS 25 MC8-I, A12LL UL2
53 specifications
Features12 differ
TypeDiffersAir conditioner indoor unitAir conditioner outdoor unit
Air conditioner functionsDiffersCooling, Dehumidifying, HeatingCooling, Heating
Seasonal efficiency rating (cooling) (SEER)Differs5.886.2
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Differs4.633.8
Cooling energy efficiency (EER, W/W)Known for one3.43Unknown — not stated by the source
Heating energy efficiency (COP, W/W)Known for one3.84Unknown — not stated by the source
Cooling capacity in watts (nominal)Differs2758 W3500 W
Cooling capacity in watts (min)Differs1300 W900 W
Cooling capacity in watts (max)Differs3662 W4000 W
Heating capacity in watts (nominal) (Average heating season)Differs2809 W4000 W
Heating capacity in watts (min)Differs910 W900 W
Heating capacity in watts (max)Differs3809 W6000 W
TimerKnown for oneYesUnknown — not stated by the source
Dehumidifying capacityKnown for one1 l/hUnknown — not stated by the source
Remotely operatedKnown for oneYesUnknown — not stated by the source
Operating temperature (cooling) (T-T)Differs-15 - 50 °C-10 - 48 °C
Operating temperature (heating) (T-T)Differs-15 - 30 °C-15 - 24 °C
Refrigerating medium weightKnown for oneUnknown — not stated by the source1 kg
Hose diameterKnown for oneUnknown — not stated by the source9.52 mm
Power7 differ
Energy efficiency class (heating) (Average heating season)DiffersA++A+
Annual energy consumption (cooling)Differs164 kWh141 kWh
Annual energy consumption (heating) (Average heating season)Differs896 kWh1179 kWh
Power consumption (cooling) (min)Known for one139 WUnknown — not stated by the source
Power consumption (cooling) (max)Differs2000 W3500 W
Power consumption (heating) (min)Known for one175 WUnknown — not stated by the source
Power consumption (heating) (max)Differs2000 W3500 W
AC input voltageDiffers230 V220-240 V
Energy efficiency class (cooling) (legacy scale)DiffersA+A++
Indoor unitidentical
Indoor unit typeKnown for oneWall-mountableUnknown — not stated by the source
Indoor unit noise level (high speed)Known for one40 dBUnknown — not stated by the source
Cooling airflow (indoor unit)Known for one683 m³/hUnknown — not stated by the source
Heating airflow (indoor unit)Known for one683 m³/hUnknown — not stated by the source
Indoor units quantityKnown for one1Unknown — not stated by the source
Indoor unit widthKnown for one80 cmUnknown — not stated by the source
Indoor unit depthKnown for one18.8 cmUnknown — not stated by the source
Indoor unit heightKnown for one27.5 cmUnknown — not stated by the source
Indoor unit weightKnown for one7.5 kgUnknown — not stated by the source
Outdoor unitidentical
Outdoor unit noise levelKnown for oneUnknown — not stated by the source65 dB
Cooling airflow (outdoor unit)Known for oneUnknown — not stated by the source1980 m³/h
Heating airflow (outdoor unit)Known for oneUnknown — not stated by the source1980 m³/h
Outdoor units quantityKnown for oneUnknown — not stated by the source1
Outdoor unit widthKnown for oneUnknown — not stated by the source77 cm
Outdoor unit depthKnown for oneUnknown — not stated by the source28.8 cm
Outdoor unit heightKnown for oneUnknown — not stated by the source54.5 cm
Outdoor unit weightKnown for oneUnknown — not stated by the source32.3 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.