Product comparison · 2 split-system air conditioners

Hotpoint AERES 20 XD0-I vs Hotpoint VENUS 35 UC8-I

Add a product
  • 30specifications compared
  • 21differ
  • 9identical
  • 28known for one product only

Key differences

  • Multi-split
    • AERES 20 XD0-I:No
    • VENUS 35 UC8-I:Yes
  • Inverter technology
    • AERES 20 XD0-I:Yes
    • VENUS 35 UC8-I:No
  • Seasonal efficiency rating (cooling) (SEER)
    • AERES 20 XD0-I:6.1
    • VENUS 35 UC8-I:6.11
  • Seasonal efficiency rating (heating) (SCOP) (Average heating season)
    • AERES 20 XD0-I:5.2
    • VENUS 35 UC8-I:3.84
  • Cooling energy efficiency (EER, W/W)
    • AERES 20 XD0-I:3.27
    • VENUS 35 UC8-I:3.26
  • Heating energy efficiency (COP, W/W)
    • AERES 20 XD0-I:4.05
    • VENUS 35 UC8-I:3.7
  • Cooling capacity in watts (nominal)
    • AERES 20 XD0-I:5133 W
    • VENUS 35 UC8-I:3490 W
  • Cooling capacity in watts (min)
    • AERES 20 XD0-I:1260 W
    • VENUS 35 UC8-I:1651 W

Side by side

Differences highlightedShow differences only (off)
Comparison of AERES 20 XD0-I, VENUS 35 UC8-I
58 specifications
Features13 differ
TypeAir conditioner indoor unitAir conditioner indoor unit
Multi-splitDiffersNoYes
Product colourWhiteWhite
Air conditioner functionsCooling, Dehumidifying, HeatingCooling, Dehumidifying, Heating
Inverter technologyDiffersYesNo
IonizerKnown for oneUnknown — not stated by the sourceNo
Seasonal efficiency rating (cooling) (SEER)Differs6.16.11
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)Known for oneUnknown — not stated by the source4.83
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Differs5.23.84
Cooling energy efficiency (EER, W/W)Differs3.273.26
Heating energy efficiency (COP, W/W)Differs4.053.7
Cooling capacity in watts (nominal)Differs5133 W3490 W
Cooling capacity in watts (min)Differs1260 W1651 W
Cooling capacity in watts (max)Differs7055 W4100 W
Heating capacity in watts (nominal) (Warmer heating season)Known for oneUnknown — not stated by the source3780 W
Heating capacity in watts (nominal) (Average heating season)Differs6446 W3270 W
Heating capacity in watts (min)Differs1906 W1181 W
Heating capacity in watts (max)Differs6900 W4000 W
Cooling capacity (min)Known for oneUnknown — not stated by the source5637 BTU/h
Cooling capacity (max)Known for oneUnknown — not stated by the source13997 BTU/h
Heating capacity (min)Known for oneUnknown — not stated by the source4029 BTU/h
Heating capacity (max)Known for oneUnknown — not stated by the source13656 BTU/h
Refrigerating mediumR410AR410A
Dehumidifying capacityDiffers1 l/h1.2 l/h
Remotely operatedYesYes
Built-in displayKnown for oneYesUnknown — not stated by the source
TimerKnown for oneYesUnknown — not stated by the source
Refrigerating medium weightKnown for one1.9 kgUnknown — not stated by the source
Compressor typeKnown for oneRotaryUnknown — not stated by the source
Operating temperature (cooling) (T-T)Known for one-15 - 50 °CUnknown — not stated by the source
Operating temperature (heating) (T-T)Known for one-15 - 30 °CUnknown — not stated by the source
Power3 differ
Energy efficiency class (heating) (Average heating season)Known for oneUnknown — not stated by the sourceA
Energy efficiency class (heating) (Colder heating season)Known for oneUnknown — not stated by the sourceNo
Energy efficiency class (heating) (Warmer heating season)Known for oneUnknown — not stated by the sourceA++
Annual energy consumption (cooling)Differs295 kWh200 kWh
Annual energy consumption (heating) (Warmer heating season)Differs1527 kWh1095 kWh
Annual energy consumption (heating) (Average heating season)Differs1988 kWh1191 kWh
Power consumption (cooling) (min)Known for oneUnknown — not stated by the source155 W
Power consumption (cooling) (max)Known for oneUnknown — not stated by the source1600 W
Power consumption (heating) (min)Known for oneUnknown — not stated by the source202 W
Power consumption (heating) (max)Known for oneUnknown — not stated by the source1600 W
AC input voltage230 V230 V
AC input frequency50 Hz50 Hz
Energy efficiency class (cooling) (legacy scale)A++A++
Design load (cooling)Known for one5.13 kWUnknown — not stated by the source
Design load (heating) (Average heating season)Known for one5.75 kWUnknown — not stated by the source
Design load (heating) (Warmer heating season)Known for one5.67 kWUnknown — not stated by the source
Networkidentical
Wi-FiKnown for oneUnknown — not stated by the sourceNo
Indoor unit5 differ
Indoor unit typeWall-mountableWall-mountable
Indoor unit noise level (high speed)Differs52 dB40 dB
Indoor unit widthDiffers75 cm85 cm
Indoor unit depthDiffers19.8 cm20.8 cm
Indoor unit heightDiffers28 cm27 cm
Indoor unit weightDiffers7 kg8.5 kg
Indoor unit International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIPX0
Cooling airflow (indoor unit)Known for one550 m³/hUnknown — not stated by the source
Heating airflow (indoor unit)Known for one550 m³/hUnknown — not stated by the source
Indoor units quantityKnown for one1Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.