Product comparison · 2 split-system air conditioners

Hisense AS-24UR4SDBTD5 air conditioner Split system White vs LG ARTCWHITE12.SET air conditioner Split system White

Add a product
  • 29specifications compared
  • 20differ
  • 9identical
  • 25known for one product only

Key differences

  • Seasonal efficiency rating (cooling) (SEER)
    • AS-24UR4SDBTD5 air conditioner Split system White:5.6
    • ARTCWHITE12.SET air conditioner Split system White:6.1
  • Seasonal efficiency rating (heating) (SCOP) (Average heating season)
    • AS-24UR4SDBTD5 air conditioner Split system White:3.8
    • ARTCWHITE12.SET air conditioner Split system White:4
  • Cooling capacity in watts (nominal)
    • AS-24UR4SDBTD5 air conditioner Split system White:6600 W
    • ARTCWHITE12.SET air conditioner Split system White:3500 W
  • Cooling capacity in watts (min)
    • AS-24UR4SDBTD5 air conditioner Split system White:2300 W
    • ARTCWHITE12.SET air conditioner Split system White:900 W
  • Cooling capacity in watts (max)
    • AS-24UR4SDBTD5 air conditioner Split system White:7300 W
    • ARTCWHITE12.SET air conditioner Split system White:4040 W
  • Heating capacity in watts (nominal) (Average heating season)
    • AS-24UR4SDBTD5 air conditioner Split system White:6800 W
    • ARTCWHITE12.SET air conditioner Split system White:4000 W
  • Heating capacity in watts (min)
    • AS-24UR4SDBTD5 air conditioner Split system White:2300 W
    • ARTCWHITE12.SET air conditioner Split system White:890 W
  • Heating capacity in watts (max)
    • AS-24UR4SDBTD5 air conditioner Split system White:8000 W
    • ARTCWHITE12.SET air conditioner Split system White:6000 W

Side by side

Differences highlightedShow differences only (on)
Comparison of AS-24UR4SDBTD5, ARTCWHITE12.SET
54 specifications
Features10 differ
Air conditioner functionsDiffersCooling, HeatingCooling, Dehumidifying, Heating
IonizerKnown for oneUnknown — not stated by the sourceYes
Seasonal efficiency rating (cooling) (SEER)Differs5.66.1
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Differs3.84
Cooling energy efficiency (EER, W/W)Known for oneUnknown — not stated by the source3.98
Heating energy efficiency (COP, W/W)Known for oneUnknown — not stated by the source4.17
Cooling capacity in watts (nominal)Differs6600 W3500 W
Cooling capacity in watts (min)Differs2300 W900 W
Cooling capacity in watts (max)Differs7300 W4040 W
Heating capacity in watts (nominal) (Average heating season)Differs6800 W4000 W
Heating capacity in watts (min)Differs2300 W890 W
Heating capacity in watts (max)Differs8000 W6000 W
Built-in displayDiffersYesNo
Refrigerating medium weightKnown for oneUnknown — not stated by the source1 kg
Hose length (max)Known for oneUnknown — not stated by the source20 m
Dehumidifying capacityKnown for oneUnknown — not stated by the source1.3 l/h
Operating temperature (cooling) (T-T)Known for oneUnknown — not stated by the source-10 - 48 °C
Operating temperature (heating) (T-T)Known for oneUnknown — not stated by the source-15 - 24 °C
Multi-splitKnown for oneYesUnknown — not stated by the source
Display typeKnown for oneLEDUnknown — not stated by the source
Auto fanKnown for oneYesUnknown — not stated by the source
Power2 differ
Energy efficiency class (heating) (Average heating season)DiffersAA+
Annual energy consumption (cooling)Known for oneUnknown — not stated by the source201 kWh
Annual energy consumption (heating) (Average heating season)Known for oneUnknown — not stated by the source1400 kWh
Power consumption (cooling) (max)Known for oneUnknown — not stated by the source880 W
Power consumption (heating) (max)Known for oneUnknown — not stated by the source960 W
AC input voltageKnown for oneUnknown — not stated by the source220-240 V
AC input frequencyKnown for oneUnknown — not stated by the source50 Hz
CurrentKnown for oneUnknown — not stated by the source15 A
Energy efficiency class (cooling) (legacy scale)DiffersA+A++
Power consumption (standby)Known for one1 WUnknown — not stated by the source
Indoor unit4 differ
Indoor unit noise level (high speed)Known for oneUnknown — not stated by the source57 dB
Cooling airflow (indoor unit)Known for oneUnknown — not stated by the source720 m³/h
Heating airflow (indoor unit)Known for oneUnknown — not stated by the source630 m³/h
Indoor unit widthDiffers113.1 cm88.5 cm
Indoor unit depthDiffers23 cm20.5 cm
Indoor unit heightDiffers31.5 cm28.5 cm
Indoor unit weightDiffers13 kg10 kg
Outdoor unit4 differ
Outdoor unit noise levelKnown for oneUnknown — not stated by the source65 dB
Cooling airflow (outdoor unit)Known for oneUnknown — not stated by the source1980 m³/h
Heating airflow (outdoor unit)Known for oneUnknown — not stated by the source1980 m³/h
Outdoor unit widthDiffers88.5 cm77 cm
Outdoor unit depthDiffers36.6 cm28.8 cm
Outdoor unit heightDiffers79.5 cm54.5 cm
Outdoor unit weightDiffers59 kg32.3 kg