Product comparison · 2 split-system air conditioners

Hisense AS-18UR4SFATD5 air conditioner Split system Grey, White vs LG Z12SL.NSH air conditioner Air conditioner indoor unit White

Add a product
  • 20specifications compared
  • 15differ
  • 5identical
  • 33known for one product only

Key differences

  • Type
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:Split system
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:Air conditioner indoor unit
  • Product colour
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:Grey, White
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:White
  • Seasonal efficiency rating (cooling) (SEER)
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:5.6
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:5.9
  • Cooling energy efficiency (EER, W/W)
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:3.25
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:3.62
  • Heating energy efficiency (COP, W/W)
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:3.62
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:3.72
  • Power consumption (cooling) (max)
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:2250 W
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:3500 W
  • Power consumption (heating) (max)
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:2100 W
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:3800 W
  • Indoor unit noise level (high speed)
    • AS-18UR4SFATD5 air conditioner Split system Grey, White:60 dB
    • Z12SL.NSH air conditioner Air conditioner indoor unit White:39 dB

Side by side

Differences highlightedShow differences only (on)
Comparison of AS-18UR4SFATD5, Z12SL.NSH
53 specifications
Features6 differ
TypeDiffersSplit systemAir conditioner indoor unit
Product colourDiffersGrey, WhiteWhite
Air conditioner functionsDiffersCooling, HeatingCooling, Dehumidifying, Heating
Seasonal efficiency rating (cooling) (SEER)Differs5.65.9
Cooling energy efficiency (EER, W/W)Differs3.253.62
Heating energy efficiency (COP, W/W)Differs3.623.72
Cooling capacity in watts (nominal)Known for one5000 WUnknown — not stated by the source
Cooling capacity in watts (min)Known for one2500 WUnknown — not stated by the source
Cooling capacity in watts (max)Known for one5750 WUnknown — not stated by the source
Heating capacity in watts (nominal) (Average heating season)Known for one5300 WUnknown — not stated by the source
Heating capacity in watts (min)Known for one2250 WUnknown — not stated by the source
Heating capacity in watts (max)Known for one6250 WUnknown — not stated by the source
Built-in displayKnown for oneYesUnknown — not stated by the source
Display typeKnown for oneLEDUnknown — not stated by the source
Refrigerating mediumKnown for oneR410AUnknown — not stated by the source
Compressor typeKnown for oneRotaryUnknown — not stated by the source
Remotely operatedKnown for oneYesUnknown — not stated by the source
Multi-splitKnown for oneUnknown — not stated by the sourceNo
Inverter technologyKnown for oneUnknown — not stated by the sourceYes
Cooling capacity (min)Known for oneUnknown — not stated by the source3072 BTU/h
Cooling capacity (max)Known for oneUnknown — not stated by the source13789 BTU/h
Heating capacity (min)Known for oneUnknown — not stated by the source3038 BTU/h
Heating capacity (max)Known for oneUnknown — not stated by the source17046 BTU/h
Dehumidifying capacityKnown for oneUnknown — not stated by the source1.3 l/h
Power2 differ
Power consumption (cooling) (min)Known for one650 WUnknown — not stated by the source
Power consumption (cooling) (max)Differs2250 W3500 W
Power consumption (heating) (min)Known for one600 WUnknown — not stated by the source
Power consumption (heating) (max)Differs2100 W3800 W
AC input voltageKnown for one220-240 VUnknown — not stated by the source
AC input frequencyKnown for one50 HzUnknown — not stated by the source
CurrentKnown for one7 AUnknown — not stated by the source
Hourly energy consumption (cooling)Known for oneUnknown — not stated by the source1.12 kWh
Hourly energy consumption (heating)Known for oneUnknown — not stated by the source1.04 kWh
Annual energy consumption (cooling)Known for oneUnknown — not stated by the source211 kWh
Annual energy consumption (heating) (Average heating season)Known for oneUnknown — not stated by the source1400 kWh
Indoor unit7 differ
Indoor unit noise level (high speed)Differs60 dB39 dB
Cooling airflow (indoor unit)Differs850 m³/h720 m³/h
Heating airflow (indoor unit)Differs850 m³/h600 m³/h
Indoor unit widthDiffers96 cm79.8 cm
Indoor unit depthDiffers23 cm21.4 cm
Indoor unit heightDiffers31.5 cm29.2 cm
Indoor unit weightDiffers12 kg8.5 kg
Outdoor unitidentical
Outdoor unit noise levelKnown for one65 dBUnknown — not stated by the source
Outdoor units quantityKnown for one1Unknown — not stated by the source
Outdoor unit widthKnown for one83 cmUnknown — not stated by the source
Outdoor unit depthKnown for one28.5 cmUnknown — not stated by the source
Outdoor unit heightKnown for one62.9 cmUnknown — not stated by the source
Outdoor unit weightKnown for one39 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.