Product comparison · 2 split-system air conditioners

Fujitsu ASY71Ui-LF Split system White vs Fujitsu AUY36UiAT Split system White

Add a product
  • 32specifications compared
  • 23differ
  • 9identical
  • 12known for one product only

Key differences

  • Cooling capacity in watts (max)
    • ASY71Ui-LF Split system White:8000 W
    • AUY36UiAT Split system White:10000 W
  • Heating capacity in watts (max)
    • ASY71Ui-LF Split system White:10600 W
    • AUY36UiAT Split system White:11200 W
  • Operating temperature (cooling) (T-T)
    • ASY71Ui-LF Split system White:-10 - 46 °C
    • AUY36UiAT Split system White:-15 - 46 °C
  • Power consumption (cooling) (max)
    • ASY71Ui-LF Split system White:2200 W
    • AUY36UiAT Split system White:2400 W
  • Power consumption (heating) (max)
    • ASY71Ui-LF Split system White:2210 W
    • AUY36UiAT Split system White:2560 W
  • AC input voltage
    • ASY71Ui-LF Split system White:230 V
    • AUY36UiAT Split system White:400 V
  • Current
    • ASY71Ui-LF Split system White:9.7 A
    • AUY36UiAT Split system White:10 A
  • Energy efficiency class (cooling) (legacy scale)
    • ASY71Ui-LF Split system White:A++
    • AUY36UiAT Split system White:A

Side by side

Differences highlightedShow differences only (off)
Comparison of ASY71Ui-LF, AUY36UiAT
44 specifications
Features4 differ
TypeSplit systemSplit system
Product colourWhiteWhite
Air conditioner functionsDiffersCooling, HeatingCooling, Dehumidifying, Heating
Inverter technologyYesYes
Seasonal efficiency rating (cooling) (SEER)Known for one6.11Unknown — not stated by the source
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Known for one3.8Unknown — not stated by the source
Cooling capacity in watts (nominal)Known for one7100 WUnknown — not stated by the source
Cooling capacity in watts (min)Known for one900 WUnknown — not stated by the source
Cooling capacity in watts (max)Differs8000 W10000 W
Heating capacity in watts (nominal) (Average heating season)Known for one8000 WUnknown — not stated by the source
Heating capacity in watts (min)Known for one900 WUnknown — not stated by the source
Heating capacity in watts (max)Differs10600 W11200 W
TimerYesYes
Refrigerating mediumR410AR410A
Operating temperature (cooling) (T-T)Differs-10 - 46 °C-15 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C-15 - 24 °C
Cooling energy efficiency (EER, W/W)Known for oneUnknown — not stated by the source4.1
Heating energy efficiency (COP, W/W)Known for oneUnknown — not stated by the source4.38
Compressor typeKnown for oneUnknown — not stated by the sourceRotary
Dehumidifying capacityKnown for oneUnknown — not stated by the source3 l/h
Power5 differ
Energy efficiency class (heating) (Average heating season)AA
Power consumption (cooling) (max)Differs2200 W2400 W
Power consumption (heating) (max)Differs2210 W2560 W
AC input voltageDiffers230 V400 V
AC input frequencyKnown for one50 HzUnknown — not stated by the source
CurrentDiffers9.7 A10 A
Energy efficiency class (cooling) (legacy scale)DiffersA++A
Indoor unit8 differ
Indoor unit typeDiffersWall-mountableCeiling
Indoor unit noise level (high speed)Differs49 dB51 dB
Cooling airflow (indoor unit)Differs1100 m³/h1800 m³/h
Heating airflow (indoor unit)Differs1100 m³/h1800 m³/h
Indoor units quantity11
Indoor unit widthDiffers99.8 cm84 cm
Indoor unit depthDiffers23.8 cm84 cm
Indoor unit heightDiffers32 cm28.8 cm
Indoor unit weightDiffers14 kg27 kg
Outdoor unit6 differ
Outdoor unit noise levelKnown for one55 dBUnknown — not stated by the source
Cooling airflow (outdoor unit)Differs2340 m³/h6200 m³/h
Heating airflow (outdoor unit)Differs2340 m³/h6200 m³/h
Outdoor units quantity11
Outdoor unit widthDiffers79 cm90 cm
Outdoor unit depthDiffers29.8 cm33 cm
Outdoor unit heightDiffers62 cm129 cm
Outdoor unit weightDiffers41 kg107 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More split-system air conditioner comparisons

All split-system air conditioner comparisons