Product comparison · 2 split-system air conditioners

Ariston DUAL 55 XD0B-O vs LG AVNQ36GKLA0 air conditioner Split system White

Add a product
  • 16specifications compared
  • 13differ
  • 3identical
  • 39known for one product only

Key differences

  • Type
    • DUAL 55 XD0B-O:Air conditioner outdoor unit
    • AVNQ36GKLA0 air conditioner Split system White:Split system
  • Cooling energy efficiency (EER, W/W)
    • DUAL 55 XD0B-O:2.89
    • AVNQ36GKLA0 air conditioner Split system White:3.02
  • Cooling capacity (max)
    • DUAL 55 XD0B-O:18419 BTU/h
    • AVNQ36GKLA0 air conditioner Split system White:34100 BTU/h
  • Compressor type
    • DUAL 55 XD0B-O:Rotary
    • AVNQ36GKLA0 air conditioner Split system White:Twin Rotary
  • Operating temperature (cooling) (T-T)
    • DUAL 55 XD0B-O:-15 - 50 °C
    • AVNQ36GKLA0 air conditioner Split system White:-5 - 48 °C
  • AC input voltage
    • DUAL 55 XD0B-O:230 V
    • AVNQ36GKLA0 air conditioner Split system White:220-240 V
  • AC input frequency
    • DUAL 55 XD0B-O:50 Hz
    • AVNQ36GKLA0 air conditioner Split system White:50 - 60 Hz
  • Outdoor unit noise level
    • DUAL 55 XD0B-O:65 dB
    • AVNQ36GKLA0 air conditioner Split system White:48 dB

Side by side

Differences highlightedShow differences only (off)
Comparison of DUAL 55 XD0B-O, AVNQ36GKLA0
55 specifications
Features6 differ
TypeDiffersAir conditioner outdoor unitSplit system
Multi-splitKnown for oneYesUnknown — not stated by the source
Product colourWhiteWhite
Air conditioner functionsDiffersCooling, Dehumidifying, Heating, VentilatingCooling, Dehumidifying
Inverter technologyYesYes
Seasonal efficiency rating (cooling) (SEER)Known for one5.6Unknown — not stated by the source
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)Known for one4.15Unknown — not stated by the source
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Known for one3.8Unknown — not stated by the source
Cooling energy efficiency (EER, W/W)Differs2.893.02
Heating energy efficiency (COP, W/W)Known for one3.33Unknown — not stated by the source
Cooling capacity in watts (nominal)Known for one5034 WUnknown — not stated by the source
Cooling capacity in watts (min)Known for one1183 WUnknown — not stated by the source
Cooling capacity in watts (max)Known for one5395 WUnknown — not stated by the source
Heating capacity in watts (nominal) (Average heating season)Known for one4427 WUnknown — not stated by the source
Heating capacity in watts (min)Known for one1250 WUnknown — not stated by the source
Heating capacity in watts (max)Known for one5708 WUnknown — not stated by the source
Cooling capacity (min)Known for one4039 BTU/hUnknown — not stated by the source
Cooling capacity (max)Differs18419 BTU/h34100 BTU/h
Heating capacity (min)Known for one4268 BTU/hUnknown — not stated by the source
Heating capacity (max)Known for one19487 BTU/hUnknown — not stated by the source
Refrigerating mediumR410AR410A
Refrigerating medium weightKnown for one1.9 kgUnknown — not stated by the source
Compressor typeDiffersRotaryTwin Rotary
Remotely operatedKnown for oneYesUnknown — not stated by the source
Operating temperature (cooling) (T-T)Differs-15 - 50 °C-5 - 48 °C
Operating temperature (heating) (T-T)Known for one-15 - 30 °CUnknown — not stated by the source
Dehumidifying capacityKnown for oneUnknown — not stated by the source2.7 l/h
Power2 differ
Energy efficiency class (heating) (Average heating season)Known for oneAUnknown — not stated by the source
Energy efficiency class (heating) (Warmer heating season)Known for oneA+Unknown — not stated by the source
Annual energy consumption (cooling)Known for one315 kWhUnknown — not stated by the source
Annual energy consumption (heating) (Warmer heating season)Known for one1536 kWhUnknown — not stated by the source
Annual energy consumption (heating) (Average heating season)Known for one1631 kWhUnknown — not stated by the source
Power consumption (cooling) (min)Known for one106 WUnknown — not stated by the source
Power consumption (cooling) (max)Known for one2228 WUnknown — not stated by the source
Power consumption (heating) (min)Known for one248 WUnknown — not stated by the source
Power consumption (heating) (max)Known for one1941 WUnknown — not stated by the source
AC input voltageDiffers230 V220-240 V
AC input frequencyDiffers50 Hz50 - 60 Hz
CurrentKnown for one20 AUnknown — not stated by the source
Energy efficiency class (cooling) (legacy scale)Known for oneA+Unknown — not stated by the source
Outdoor unit5 differ
Outdoor unit noise levelDiffers65 dB48 dB
Cooling airflow (outdoor unit)Known for one2100 m³/hUnknown — not stated by the source
Heating airflow (outdoor unit)Known for one2100 m³/hUnknown — not stated by the source
Outdoor units quantityKnown for one1Unknown — not stated by the source
Outdoor unit widthDiffers80 cm95 cm
Outdoor unit depthDiffers33.3 cm33 cm
Outdoor unit heightDiffers55.4 cm83 cm
Outdoor unit weightDiffers37.8 kg65 kg
Indoor unitidentical
Indoor unit typeKnown for oneUnknown — not stated by the sourceCeiling
Indoor unit noise level (high speed)Known for oneUnknown — not stated by the source45 dB
Indoor unit widthKnown for oneUnknown — not stated by the source135 cm
Indoor unit depthKnown for oneUnknown — not stated by the source22 cm
Indoor unit heightKnown for oneUnknown — not stated by the source65 cm
Indoor unit weightKnown for oneUnknown — not stated by the source29 kg
Technical detailsidentical
AirflowKnown for oneUnknown — not stated by the source1284 m³/h

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More split-system air conditioner comparisons

All split-system air conditioner comparisons