Product comparison · 2 split-system air conditioners

Ariston Aeres 30 UD0-I vs Samsung F-AR12NC air conditioner Split system White

Add a product
  • 33specifications compared
  • 24differ
  • 9identical
  • 29known for one product only

Key differences

  • Type
    • Aeres 30 UD0-I:Air conditioner indoor unit
    • F-AR12NC air conditioner Split system White:Split system
  • Seasonal efficiency rating (cooling) (SEER)
    • Aeres 30 UD0-I:6.68
    • F-AR12NC air conditioner Split system White:5.6
  • Seasonal efficiency rating (heating) (SCOP) (Average heating season)
    • Aeres 30 UD0-I:4.00
    • F-AR12NC air conditioner Split system White:4
  • Cooling capacity in watts (nominal)
    • Aeres 30 UD0-I:2772 W
    • F-AR12NC air conditioner Split system White:3500 W
  • Cooling capacity in watts (min)
    • Aeres 30 UD0-I:1212 W
    • F-AR12NC air conditioner Split system White:1300 W
  • Cooling capacity in watts (max)
    • Aeres 30 UD0-I:3465 W
    • F-AR12NC air conditioner Split system White:4000 W
  • Heating capacity in watts (min)
    • Aeres 30 UD0-I:1084 W
    • F-AR12NC air conditioner Split system White:950 W
  • Heating capacity in watts (max)
    • Aeres 30 UD0-I:3690 W
    • F-AR12NC air conditioner Split system White:5100 W

Side by side

Differences highlightedShow differences only (on)
Comparison of Aeres 30 UD0-I, F-AR12NC
62 specifications
Features11 differ
TypeDiffersAir conditioner indoor unitSplit system
Air conditioner functionsDiffersCooling, Dehumidifying, Heating, VentilatingCooling, Dehumidifying, Heating
Seasonal efficiency rating (cooling) (SEER)Differs6.685.6
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)Known for one5.12Unknown — not stated by the source
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Differs4.004
Cooling energy efficiency (EER, W/W)Known for one3.83Unknown — not stated by the source
Heating energy efficiency (COP, W/W)Known for one3.95Unknown — not stated by the source
Cooling capacity in watts (nominal)Differs2772 W3500 W
Cooling capacity in watts (min)Differs1212 W1300 W
Cooling capacity in watts (max)Differs3465 W4000 W
Heating capacity in watts (nominal) (Warmer heating season)Known for one2930 WUnknown — not stated by the source
Heating capacity in watts (min)Differs1084 W950 W
Heating capacity in watts (max)Differs3690 W5100 W
Cooling capacity (min)Known for one4138 BTU/hUnknown — not stated by the source
Cooling capacity (max)Known for one11830 BTU/hUnknown — not stated by the source
Heating capacity (min)Known for one3701 BTU/hUnknown — not stated by the source
Heating capacity (max)Known for one12598 BTU/hUnknown — not stated by the source
Built-in displayKnown for oneYesUnknown — not stated by the source
Compressor typeKnown for oneRotaryUnknown — not stated by the source
Operating temperature (cooling) (T-T)Differs-15 - 50 °C-10 - 46 °C
Operating temperature (heating) (T-T)Differs-15 - 30 °C-15 - 24 °C
Heating capacity in watts (nominal) (Average heating season)Known for oneUnknown — not stated by the source4000 W
TimerKnown for oneUnknown — not stated by the sourceYes
Refrigerating medium weightKnown for oneUnknown — not stated by the source950 g
Hose length (max)Known for oneUnknown — not stated by the source15 m
Dehumidifying capacityKnown for oneUnknown — not stated by the source1.5 l/h
Power7 differ
Energy efficiency class (heating) (Warmer heating season)Known for oneA+++Unknown — not stated by the source
Annual energy consumption (cooling)Differs145 kWh219 kWh
Annual energy consumption (heating) (Warmer heating season)Known for one739 kWhUnknown — not stated by the source
Annual energy consumption (heating) (Average heating season)Differs1068 kWh840 kWh
Power consumption (cooling) (min)Known for one115 WUnknown — not stated by the source
Power consumption (cooling) (max)Differs2100 W1030 W
Power consumption (heating) (min)Known for one179 WUnknown — not stated by the source
Power consumption (heating) (max)Differs2100 W1100 W
AC input voltageKnown for one230 VUnknown — not stated by the source
AC input frequencyKnown for one50 HzUnknown — not stated by the source
Design load (cooling)Differs2.77 kW3.5 kW
Design load (heating) (Average heating season)Differs3.05 kW2.4 kW
Design load (heating) (Warmer heating season)Known for one2.7 kWUnknown — not stated by the source
Energy efficiency class (cooling) (legacy scale)DiffersA++A+
Indoor unit6 differ
Indoor unit noise level (high speed)Differs52 dB56 dB
Cooling airflow (indoor unit)Differs550 m³/h720 m³/h
Heating airflow (indoor unit)Differs550 m³/h720 m³/h
Indoor unit widthDiffers75 cm82.6 cm
Indoor unit depthDiffers19.8 cm27.5 cm
Indoor unit heightDiffers28 cm26 cm
Indoor unit weightKnown for oneUnknown — not stated by the source9.5 kg
Outdoor unitidentical
Outdoor unit noise levelKnown for oneUnknown — not stated by the source62 dB
Outdoor units quantityKnown for oneUnknown — not stated by the source1
Outdoor unit widthKnown for oneUnknown — not stated by the source79 cm
Outdoor unit depthKnown for oneUnknown — not stated by the source28.5 cm
Outdoor unit heightKnown for oneUnknown — not stated by the source54.5 cm
Outdoor unit weightKnown for oneUnknown — not stated by the source29.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More split-system air conditioner comparisons

All split-system air conditioner comparisons