Product comparison · 2 split-system air conditioners

Ariston Aeres 30 UD0-I vs Samsung F-AR09NC air conditioner Split system White

Add a product
  • 33specifications compared
  • 24differ
  • 9identical
  • 29known for one product only

Key differences

  • Type
    • Aeres 30 UD0-I:Air conditioner indoor unit
    • F-AR09NC air conditioner Split system White:Split system
  • Seasonal efficiency rating (cooling) (SEER)
    • Aeres 30 UD0-I:6.68
    • F-AR09NC air conditioner Split system White:5.6
  • Seasonal efficiency rating (heating) (SCOP) (Average heating season)
    • Aeres 30 UD0-I:4.00
    • F-AR09NC air conditioner Split system White:4
  • Cooling capacity in watts (nominal)
    • Aeres 30 UD0-I:2772 W
    • F-AR09NC air conditioner Split system White:2500 W
  • Cooling capacity in watts (min)
    • Aeres 30 UD0-I:1212 W
    • F-AR09NC air conditioner Split system White:1300 W
  • Cooling capacity in watts (max)
    • Aeres 30 UD0-I:3465 W
    • F-AR09NC air conditioner Split system White:3300 W
  • Heating capacity in watts (min)
    • Aeres 30 UD0-I:1084 W
    • F-AR09NC air conditioner Split system White:950 W
  • Heating capacity in watts (max)
    • Aeres 30 UD0-I:3690 W
    • F-AR09NC air conditioner Split system White:4700 W

Side by side

Differences highlightedShow differences only (off)
Comparison of Aeres 30 UD0-I, F-AR09NC
62 specifications
Features11 differ
TypeDiffersAir conditioner indoor unitSplit system
Multi-splitNoNo
Product colourWhiteWhite
Air conditioner functionsDiffersCooling, Dehumidifying, Heating, VentilatingCooling, Dehumidifying, Heating
Inverter technologyYesYes
Seasonal efficiency rating (cooling) (SEER)Differs6.685.6
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)Known for one5.12Unknown — not stated by the source
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Differs4.004
Cooling energy efficiency (EER, W/W)Known for one3.83Unknown — not stated by the source
Heating energy efficiency (COP, W/W)Known for one3.95Unknown — not stated by the source
Cooling capacity in watts (nominal)Differs2772 W2500 W
Cooling capacity in watts (min)Differs1212 W1300 W
Cooling capacity in watts (max)Differs3465 W3300 W
Heating capacity in watts (nominal) (Warmer heating season)Known for one2930 WUnknown — not stated by the source
Heating capacity in watts (min)Differs1084 W950 W
Heating capacity in watts (max)Differs3690 W4700 W
Cooling capacity (min)Known for one4138 BTU/hUnknown — not stated by the source
Cooling capacity (max)Known for one11830 BTU/hUnknown — not stated by the source
Heating capacity (min)Known for one3701 BTU/hUnknown — not stated by the source
Heating capacity (max)Known for one12598 BTU/hUnknown — not stated by the source
Built-in displayKnown for oneYesUnknown — not stated by the source
Refrigerating mediumR410AR410A
Compressor typeKnown for oneRotaryUnknown — not stated by the source
Remotely operatedYesYes
Operating temperature (cooling) (T-T)Differs-15 - 50 °C-10 - 46 °C
Operating temperature (heating) (T-T)Differs-15 - 30 °C-15 - 24 °C
Heating capacity in watts (nominal) (Average heating season)Known for oneUnknown — not stated by the source3300 W
TimerKnown for oneUnknown — not stated by the sourceYes
Refrigerating medium weightKnown for oneUnknown — not stated by the source950 g
Hose length (max)Known for oneUnknown — not stated by the source15 m
Dehumidifying capacityKnown for oneUnknown — not stated by the source1 l/h
Power7 differ
Energy efficiency class (heating) (Average heating season)A+A+
Energy efficiency class (heating) (Warmer heating season)Known for oneA+++Unknown — not stated by the source
Annual energy consumption (cooling)Differs145 kWh156 kWh
Annual energy consumption (heating) (Warmer heating season)Known for one739 kWhUnknown — not stated by the source
Annual energy consumption (heating) (Average heating season)Differs1068 kWh840 kWh
Power consumption (cooling) (min)Known for one115 WUnknown — not stated by the source
Power consumption (cooling) (max)Differs2100 W670 W
Power consumption (heating) (min)Known for one179 WUnknown — not stated by the source
Power consumption (heating) (max)Differs2100 W910 W
AC input voltageKnown for one230 VUnknown — not stated by the source
AC input frequencyKnown for one50 HzUnknown — not stated by the source
Design load (cooling)Differs2.77 kW2.5 kW
Design load (heating) (Average heating season)Differs3.05 kW2.4 kW
Design load (heating) (Warmer heating season)Known for one2.7 kWUnknown — not stated by the source
Energy efficiency class (cooling) (legacy scale)DiffersA++A+
Networkidentical
Wi-FiNoNo
Indoor unit6 differ
Indoor unit typeWall-mountableWall-mountable
Indoor unit noise level (high speed)Differs52 dB54 dB
Cooling airflow (indoor unit)Differs550 m³/h660 m³/h
Heating airflow (indoor unit)Differs550 m³/h660 m³/h
Indoor units quantity11
Indoor unit widthDiffers75 cm82.6 cm
Indoor unit depthDiffers19.8 cm27.5 cm
Indoor unit heightDiffers28 cm26 cm
Indoor unit weightKnown for oneUnknown — not stated by the source9.5 kg
Outdoor unitidentical
Outdoor unit noise levelKnown for oneUnknown — not stated by the source59 dB
Outdoor units quantityKnown for oneUnknown — not stated by the source1
Outdoor unit widthKnown for oneUnknown — not stated by the source79 cm
Outdoor unit depthKnown for oneUnknown — not stated by the source28.5 cm
Outdoor unit heightKnown for oneUnknown — not stated by the source54.5 cm
Outdoor unit weightKnown for oneUnknown — not stated by the source29.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.