Product comparison · 2 split-system air conditioners

Ariston A-IFWH09-IMX Air conditioner indoor unit White vs Ariston Aeres 30 UD0-I

Add a product
  • 18specifications compared
  • 10differ
  • 8identical
  • 34known for one product only

Key differences

  • Multi-split
    • A-IFWH09-IMX Air conditioner indoor unit White:Yes
    • Aeres 30 UD0-I:No
  • Cooling capacity in watts (nominal)
    • A-IFWH09-IMX Air conditioner indoor unit White:2630 W
    • Aeres 30 UD0-I:2772 W
  • Heating capacity in watts (nominal) (Warmer heating season)
    • A-IFWH09-IMX Air conditioner indoor unit White:3220 W
    • Aeres 30 UD0-I:2930 W
  • Indoor unit noise level (high speed)
    • A-IFWH09-IMX Air conditioner indoor unit White:37 dB
    • Aeres 30 UD0-I:52 dB
  • Cooling airflow (indoor unit)
    • A-IFWH09-IMX Air conditioner indoor unit White:570 m³/h
    • Aeres 30 UD0-I:550 m³/h
  • Heating airflow (indoor unit)
    • A-IFWH09-IMX Air conditioner indoor unit White:570 m³/h
    • Aeres 30 UD0-I:550 m³/h
  • Indoor unit width
    • A-IFWH09-IMX Air conditioner indoor unit White:71 cm
    • Aeres 30 UD0-I:75 cm
  • Indoor unit depth
    • A-IFWH09-IMX Air conditioner indoor unit White:19 cm
    • Aeres 30 UD0-I:19.8 cm

Side by side

Differences highlightedShow differences only (off)
Comparison of A-IFWH09-IMX, Aeres 30 UD0-I
52 specifications
Features4 differ
TypeAir conditioner indoor unitAir conditioner indoor unit
Multi-splitDiffersYesNo
Product colourWhiteWhite
Air conditioner functionsDiffersCooling, HeatingCooling, Dehumidifying, Heating, Ventilating
Inverter technologyYesYes
Seasonal efficiency rating (cooling) (SEER)Known for oneUnknown — not stated by the source6.68
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)Known for oneUnknown — not stated by the source5.12
Seasonal efficiency rating (heating) (SCOP) (Average heating season)Known for oneUnknown — not stated by the source4.00
Cooling energy efficiency (EER, W/W)Known for oneUnknown — not stated by the source3.83
Heating energy efficiency (COP, W/W)Known for oneUnknown — not stated by the source3.95
Cooling capacity in watts (nominal)Differs2630 W2772 W
Cooling capacity in watts (min)Known for oneUnknown — not stated by the source1212 W
Cooling capacity in watts (max)Known for oneUnknown — not stated by the source3465 W
Heating capacity in watts (nominal) (Warmer heating season)Differs3220 W2930 W
Heating capacity in watts (min)Known for oneUnknown — not stated by the source1084 W
Heating capacity in watts (max)Known for oneUnknown — not stated by the source3690 W
Cooling capacity (min)Known for oneUnknown — not stated by the source4138 BTU/h
Cooling capacity (max)Known for oneUnknown — not stated by the source11830 BTU/h
Heating capacity (min)Known for oneUnknown — not stated by the source3701 BTU/h
Heating capacity (max)Known for oneUnknown — not stated by the source12598 BTU/h
Built-in displayKnown for oneUnknown — not stated by the sourceYes
Refrigerating mediumR410AR410A
Compressor typeKnown for oneUnknown — not stated by the sourceRotary
Remotely operatedKnown for oneUnknown — not stated by the sourceYes
Operating temperature (cooling) (T-T)Known for oneUnknown — not stated by the source-15 - 50 °C
Operating temperature (heating) (T-T)Known for oneUnknown — not stated by the source-15 - 30 °C
Hose length (max)Known for one15 mUnknown — not stated by the source
Poweridentical
Energy efficiency class (heating) (Average heating season)Known for oneUnknown — not stated by the sourceA+
Energy efficiency class (heating) (Warmer heating season)Known for oneUnknown — not stated by the sourceA+++
Annual energy consumption (cooling)Known for oneUnknown — not stated by the source145 kWh
Annual energy consumption (heating) (Warmer heating season)Known for oneUnknown — not stated by the source739 kWh
Annual energy consumption (heating) (Average heating season)Known for oneUnknown — not stated by the source1068 kWh
Power consumption (cooling) (min)Known for oneUnknown — not stated by the source115 W
Power consumption (cooling) (max)Known for oneUnknown — not stated by the source2100 W
Power consumption (heating) (min)Known for oneUnknown — not stated by the source179 W
Power consumption (heating) (max)Known for oneUnknown — not stated by the source2100 W
AC input voltage230 V230 V
AC input frequency50 Hz50 Hz
Design load (cooling)Known for oneUnknown — not stated by the source2.77 kW
Design load (heating) (Average heating season)Known for oneUnknown — not stated by the source3.05 kW
Design load (heating) (Warmer heating season)Known for oneUnknown — not stated by the source2.7 kW
Energy efficiency class (cooling) (legacy scale)Known for oneUnknown — not stated by the sourceA++
Networkidentical
Wi-FiNoNo
Indoor unit6 differ
Indoor unit typeWall-mountableWall-mountable
Indoor unit noise level (high speed)Differs37 dB52 dB
Cooling airflow (indoor unit)Differs570 m³/h550 m³/h
Heating airflow (indoor unit)Differs570 m³/h550 m³/h
Indoor units quantityKnown for oneUnknown — not stated by the source1
Indoor unit widthDiffers71 cm75 cm
Indoor unit depthDiffers19 cm19.8 cm
Indoor unit heightDiffers25 cm28 cm
Indoor unit weightKnown for one9 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.