Product comparison · 2 solar inverters

Salicru EQX2 6002-HT vs Salicru EQX2 8002-HSX

Add a product
  • 47specifications compared
  • 14differ
  • 33identical
  • 2known for one product only

Key differences

  • Output power capacity (max)
    • EQX2 6002-HT:6.6 kVA
    • EQX2 8002-HSX:8.8 kVA
  • Output operation voltage (min)
    • EQX2 6002-HT:195.5 V
    • EQX2 8002-HSX:195 V
  • MPP voltage range
    • EQX2 6002-HT:200 - 850 V
    • EQX2 8002-HSX:100 - 550 V
  • Maximum input power (DC)
    • EQX2 6002-HT:9600 W
    • EQX2 8002-HSX:12800 W
  • Maximum power
    • EQX2 6002-HT:6000 W
    • EQX2 8002-HSX:8000 W
  • DC input voltage
    • EQX2 6002-HT:1000 V
    • EQX2 8002-HSX:600 V
  • Network voltage
    • EQX2 6002-HT:400 V
    • EQX2 8002-HSX:230 V
  • Output current
    • EQX2 6002-HT:8.7 A
    • EQX2 8002-HSX:34.8 A

Side by side

Differences highlightedShow differences only (on)
Comparison of EQX2 6002-HT, EQX2 8002-HSX
49 specifications
Features14 differ
Output power capacity (max)Differs6.6 kVA8.8 kVA
Output operation voltage (min)Differs195.5 V195 V
MPP voltage rangeDiffers200 - 850 V100 - 550 V
Maximum input power (DC)Differs9600 W12800 W
Maximum powerDiffers6000 W8000 W
DC input voltageDiffers1000 V600 V
Network voltageDiffers400 V230 V
Output currentDiffers8.7 A34.8 A
Pollution degreeKnown for one2/3Unknown — not stated by the source
Short-circuit current per MPPT (max)Differs18 A20 A
Starting voltageDiffers180 V80 V
Maximum input current per MPPTDiffers13 A15 A
EfficiencyDiffers98.1%97.6%
Efficiency (EU)Differs97.3%97%
CertificationDiffersEN 61000-6-2/3, IEC 62109-IEC EN UNE 616831/2 / EN 61000-6-2/3, IEC EN UNE 60068-1/2/14/30, UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001EN 61000-6-2/3, IEC 62109-1/2 / EN 61000-6-2/3, IEC EN UNE 61683, IEC EN UNE 60068-1/2/14/30, UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001
DC disconnectorKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More solar inverter comparisons

All solar inverter comparisons