Product comparison · 2 solar inverters

Salicru EQX2 4002-HSX vs Salicru EQX2 8002-SX

Add a product
  • 47specifications compared
  • 12differ
  • 35identical
  • 7known for one product only

Key differences

The Salicru EQX2 8002-SX has 4.18 kVA more output power capacity (max) than the Salicru EQX2 4002-HSX (8.8 kVA vs 4.62 kVA). The Salicru EQX2 8002-SX has 0.5 V more output operation voltage (min) than the Salicru EQX2 4002-HSX (195.5 V vs 195 V). The Salicru EQX2 4002-HSX has 20 - 550 V more MPP voltage range than the Salicru EQX2 8002-SX (100 - 550 V vs 80 - 550 V).

  • Output power capacity (max)
    • EQX2 4002-HSX:4.62 kVA
    • EQX2 8002-SX:8.8 kVA
  • Output operation voltage (min)
    • EQX2 4002-HSX:195 V
    • EQX2 8002-SX:195.5 V
  • MPP voltage range
    • EQX2 4002-HSX:100 - 550 V
    • EQX2 8002-SX:80 - 550 V
  • Maximum input power (DC)
    • EQX2 4002-HSX:6720 W
    • EQX2 8002-SX:10400 W
  • Maximum power
    • EQX2 4002-HSX:4200 W
    • EQX2 8002-SX:8000 W
  • Output current
    • EQX2 4002-HSX:18.3 A
    • EQX2 8002-SX:34.8 A
  • Short-circuit current per MPPT (max)
    • EQX2 4002-HSX:20 A
    • EQX2 8002-SX:40 A
  • Number of strings per MPPT
    • EQX2 4002-HSX:1
    • EQX2 8002-SX:2

Side by side

Differences highlightedShow differences only (on)
Comparison of EQX2 4002-HSX, EQX2 8002-SX
54 specifications
Features11 differ
Output power capacity (max)Differs4.62 kVA8.8 kVA
Output operation voltage (min)Differs195 V195.5 V
MPP voltage rangeDiffers100 - 550 V80 - 550 V
Maximum input power (DC)Differs6720 W10400 W
Maximum powerDiffers4200 W8000 W
Output currentDiffers18.3 A34.8 A
Short-circuit current per MPPT (max)Differs20 A40 A
Number of strings per MPPTDiffers12
Maximum input current per MPPTDiffers15 A30 A
EfficiencyDiffers97.6%98.1%
Efficiency (EU)Differs97%97.6%
Efficiency (MPPT)Known for oneUnknown — not stated by the source99.9%
MaterialKnown for oneUnknown — not stated by the sourceSilicon carbide (SiC)
CertificationKnown for oneUnknown — not stated by the sourceCertificate EN 61000-6-2/3, IEC 62109-1/2 / EN 61000-6-2/3, IEC EN UNE 61683, IEC EN UNE 60068-2-1/2/14/30, UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001
CompatibilityKnown for oneEN 61000-6-2/3, IEC 62109-1/2 / EN 61000-6-2/3, IEC EN UNE 61683, IEC EN UNE 60068-1/2/14/30, UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001Unknown — not stated by the source
Designidentical
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Overvoltage categoryKnown for oneUnknown — not stated by the sourceCAT II
Weight & dimensions1 differ
WeightDiffers26 kg24 kg
Ports & interfacesidentical
Photovoltaic (PV) inputKnown for oneUnknown — not stated by the source6

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.