Product comparison · 2 solar inverters

Salicru EQX2 12002-HT vs Salicru EQX2 4002-SX

Add a product
  • 45specifications compared
  • 17differ
  • 28identical
  • 9known for one product only

Key differences

The Salicru EQX2 12002-HT has 8.58 kVA more output power capacity (max) than the Salicru EQX2 4002-SX (13.2 kVA vs 4.62 kVA). The Salicru EQX2 12002-HT has 13,740 W more maximum input power (DC) than the Salicru EQX2 4002-SX (19200 W vs 5460 W). The Salicru EQX2 12002-HT has 7,800 W more maximum power than the Salicru EQX2 4002-SX (12000 W vs 4200 W). MPP voltage range: 200 - 850 V on the Salicru EQX2 12002-HT, 100 - 550 V on the Salicru EQX2 4002-SX. Power protection features: Over voltage, Overheating, Short circuit on the Salicru EQX2 12002-HT, Over voltage on the Salicru EQX2 4002-SX.

  • Output power capacity (max)
    • EQX2 12002-HT:13.2 kVA
    • EQX2 4002-SX:4.62 kVA
  • MPP voltage range
    • EQX2 12002-HT:200 - 850 V
    • EQX2 4002-SX:100 - 550 V
  • Maximum input power (DC)
    • EQX2 12002-HT:19200 W
    • EQX2 4002-SX:5460 W
  • Maximum power
    • EQX2 12002-HT:12000 W
    • EQX2 4002-SX:4200 W
  • DC input voltage
    • EQX2 12002-HT:1000 V
    • EQX2 4002-SX:600 V
  • Network voltage
    • EQX2 12002-HT:400 V
    • EQX2 4002-SX:230 V
  • Output current
    • EQX2 12002-HT:17.4 A
    • EQX2 4002-SX:18.3 A
  • Short-circuit current per MPPT (max)
    • EQX2 12002-HT:18 A
    • EQX2 4002-SX:20 A

Side by side

Differences highlightedShow differences only (on)
Comparison of EQX2 12002-HT, EQX2 4002-SX
54 specifications
Features12 differ
Output power capacity (max)Differs13.2 kVA4.62 kVA
MPP voltage rangeDiffers200 - 850 V100 - 550 V
Maximum input power (DC)Differs19200 W5460 W
Maximum powerDiffers12000 W4200 W
DC disconnectorKnown for oneUnknown — not stated by the sourceYes
DC input voltageDiffers1000 V600 V
Network voltageDiffers400 V230 V
Number of power levelsKnown for oneUnknown — not stated by the source7
Output currentDiffers17.4 A18.3 A
Short-circuit current per MPPT (max)Differs18 A20 A
Starting voltageDiffers180 V80 V
Maximum input current per MPPTDiffers13 A15 A
EfficiencyDiffers98.2%98.1%
Efficiency (EU)Differs97.4%97.5%
Efficiency (MPPT)Known for oneUnknown — not stated by the source99.9%
MaterialKnown for oneUnknown — not stated by the sourceSilicon carbide (SiC)
CertificationKnown for oneUnknown — not stated by the sourceCertificate EN 61000-6-2/3, IEC 62109-1/2 / EN 61000-6-2/3, IEC EN UNE 61683, IEC EN UNE 60068-2-1/2/14/30, UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001
Design1 differ
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Power protection featuresDiffersOver voltage, Overheating, Short circuitOver voltage
Overvoltage categoryKnown for oneUnknown — not stated by the sourceCAT II
Weight & dimensions4 differ
WidthDiffers550 mm410 mm
DepthDiffers175 mm120 mm
HeightDiffers410 mm360 mm
WeightDiffers28 kg13 kg
Ports & interfacesidentical
Photovoltaic (PV) inputKnown for oneUnknown — not stated by the source4
Networkidentical
Wi-FiKnown for oneYesUnknown — not stated by the source