The Salicru EQX2 12002-HT has 8.58 kVA more output power capacity (max) than the Salicru EQX2 4002-HT (13.2 kVA vs 4.62 kVA). The Salicru EQX2 12002-HT has 0.5 V more output operation voltage (min) than the Salicru EQX2 4002-HT (195.5 V vs 195 V). The Salicru EQX2 12002-HT has 100 - 850 V more MPP voltage range than the Salicru EQX2 4002-HT (200 - 850 V vs 100 - 850 V). Power protection features: Over voltage, Overheating, Short circuit on the Salicru EQX2 12002-HT, Over voltage on the Salicru EQX2 4002-HT.

  • Output power capacity (max)
    • EQX2 12002-HT:13.2 kVA
    • EQX2 4002-HT:4.62 kVA
  • Output operation voltage (min)
    • EQX2 12002-HT:195.5 V
    • EQX2 4002-HT:195 V
  • MPP voltage range
    • EQX2 12002-HT:200 - 850 V
    • EQX2 4002-HT:100 - 850 V
  • Maximum input power (DC)
    • EQX2 12002-HT:19200 W
    • EQX2 4002-HT:6400 W
  • Maximum power
    • EQX2 12002-HT:12000 W
    • EQX2 4002-HT:4000 W
  • Output current
    • EQX2 12002-HT:17.4 A
    • EQX2 4002-HT:5.8 A
  • Starting voltage
    • EQX2 12002-HT:180 V
    • EQX2 4002-HT:150 V
  • Efficiency
    • EQX2 12002-HT:98.2%
    • EQX2 4002-HT:98.1%

Side by side

Differences highlightedShow differences only (on)
Comparison of EQX2 12002-HT, EQX2 4002-HT
49 specifications
Features9 differ
Output power capacity (max)Differs13.2 kVA4.62 kVA
Output operation voltage (min)Differs195.5 V195 V
MPP voltage rangeDiffers200 - 850 V100 - 850 V
Maximum input power (DC)Differs19200 W6400 W
Maximum powerDiffers12000 W4000 W
DC disconnectorKnown for oneUnknown — not stated by the sourceYes
Number of power levelsKnown for oneUnknown — not stated by the source7
Output currentDiffers17.4 A5.8 A
Starting voltageDiffers180 V150 V
EfficiencyDiffers98.2%98.1%
Efficiency (EU)Differs97.4%97.3%
CertificationKnown for oneUnknown — not stated by the sourceEN 61000-6-2/3, IEC 62109-1/2 / EN 61000-6-2/3, IEC EN UNE 61683, IEC EN UNE 60068-1/2/14/30,UNE EN 62116:2014, IEC 61727:2004, UNE 217002:2020, UNE 217001:2020, ISO 9001, ISO 14001, ISO 45001
Design1 differ
Power protection featuresDiffersOver voltage, Overheating, Short circuitOver voltage
Weight & dimensions1 differ
WeightDiffers28 kg26 kg