Product comparison · 2 raid controllers

Lenovo 7Y37A01087 RAID controller PCI Express x8 3.0 vs Lenovo ThinkSystem RAID 940-16i

Add a product
  • 10specifications compared
  • 6differ
  • 4identical
  • 11known for one product only

Key differences

The Lenovo ThinkSystem RAID 940-16i has 1 more PCI Express slots version than the Lenovo 7Y37A01087 RAID controller PCI Express x8 3.0 (4.0 vs 3.0). The Lenovo ThinkSystem RAID 940-16i has 3,904 MB more internal memory than the Lenovo 7Y37A01087 RAID controller PCI Express x8 3.0 (8000 MB vs 4096 MB). Supported storage drive interfaces: SAS, Serial ATA on the Lenovo 7Y37A01087 RAID controller PCI Express x8 3.0, SAS on the Lenovo ThinkSystem RAID 940-16i. RAID levels: 0, 1, 5, 6, 10, 50, 60 on the Lenovo 7Y37A01087 RAID controller PCI Express x8 3.0, 0, 1, 5, 6, 10, 50, 60, JBOD on the Lenovo ThinkSystem RAID 940-16i. Operating relative humidity (H-H): 20 - 90% on the Lenovo 7Y37A01087 RAID controller PCI Express x8 3.0, 20 - 80% on the Lenovo ThinkSystem RAID 940-16i.

  • Supported storage drive interfaces
    • 7Y37A01087 RAID controller PCI Express x8 3.0:SAS, Serial ATA
    • ThinkSystem RAID 940-16i:SAS
  • PCI Express slots version
    • 7Y37A01087 RAID controller PCI Express x8 3.0:3.0
    • ThinkSystem RAID 940-16i:4.0
  • RAID levels
    • 7Y37A01087 RAID controller PCI Express x8 3.0:0, 1, 5, 6, 10, 50, 60
    • ThinkSystem RAID 940-16i:0, 1, 5, 6, 10, 50, 60, JBOD
  • Internal memory
    • 7Y37A01087 RAID controller PCI Express x8 3.0:4096 MB
    • ThinkSystem RAID 940-16i:8000 MB
  • Operating relative humidity (H-H)
    • 7Y37A01087 RAID controller PCI Express x8 3.0:20 - 90%
    • ThinkSystem RAID 940-16i:20 - 80%

Side by side

Differences highlightedShow differences only (off)
Comparison of 7Y37A01087, ThinkSystem RAID 940-16i
21 specifications
Ports & interfaces2 differ
Supported storage drive interfacesDiffersSAS, Serial ATASAS
Host interfacePCI Express x8PCI Express x8
PCI Express slots versionDiffers3.04.0
Internal mini-SAS HD portsKnown for one2Unknown — not stated by the source
Performance3 differ
RAID Level MigrationKnown for oneUnknown — not stated by the sourceYes
RAID levelsDiffers0, 1, 5, 6, 10, 50, 600, 1, 5, 6, 10, 50, 60, JBOD
Data transfer rateKnown for oneUnknown — not stated by the source12 Gbit/s
SSD supportYesYes
Internal memoryDiffers4096 MB8000 MB
Number of devices supportedKnown for oneUnknown — not stated by the source16
Hot-swapKnown for oneUnknown — not stated by the sourceYes
CertificationDiffersFCC Part 15 Class A Australia/New Zealand (AS/NZS CISPR 22) Canada (ICES-003 Class B) Europe (EN55022/EN55024) Japan (VCCI V-3) Korea (RRA no 2013-24 & 25) RoHS compliant EN/IEC/UL 60950 Taiwan (CNS 13438) USA (FCC 47 CFR part 15 Subpart B class B) WEEEUSA (FCC 47 CFR part 15 Subpart B, class B) Canada (ICES -003, Class B) Taiwan (CNS 13438) Japan (VCCI V-3) Australia/New Zealand (AS/NZS CISPR 22) Korea (RRA no 2013-24 & 25) Europe (EN55022/EN55024) Safety: EN/ IEC/ UL 60950 RoHS WEEE
Compatible productsKnown for oneUnknown — not stated by the sourceSR665 (7D2W/7D2V), SR645 (7D2Y/7D2X)
JBOD functionKnown for oneYesUnknown — not stated by the source
S.M.A.R.T. supportKnown for oneYesUnknown — not stated by the source
System requirementsidentical
Compatible operating systemsKnown for oneUnknown — not stated by the sourceMicrosoft Windows Server 2016 Microsoft Windows Server 2019 Red Hat Enterprise Linux 8.1 SUSE Linux Enterprise Server 12 SP5 SUSE Linux Enterprise Server 12 SP5 with Xen SUSE Linux Enterprise Server 15 SP1 SUSE Linux Enterprise Server 15 SP1 with Xen VMware vSphere Hypervisor (ESXi) 6.7 U3 VMware vS
Operational conditions1 differ
Operating temperature (T-T)10 - 55 °C10 - 55 °C
Operating relative humidity (H-H)Differs20 - 90%20 - 80%
Storage relative humidity (H-H)5 - 95%5 - 95%
Storage temperature (T-T)Known for one-40 - 70 °CUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source84733080

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More raid controller comparisons