Product comparison · 2 raid controllers

Fujitsu PRAID CP500i FH/LP vs Lenovo 4XC0G88835 RAID controller

Add a product
  • 2specifications compared
  • 2differ
  • 0identical
  • 16known for one product only

Key differences

RAID levels: 0, 1, 5, 10, 50 on the Fujitsu PRAID CP500i FH/LP, 5 on the Lenovo 4XC0G88835 RAID controller. Compatible products: PRIMERGY Server on the Fujitsu PRAID CP500i FH/LP, 4XC0G88834 on the Lenovo 4XC0G88835 RAID controller.

  • RAID levels
    • PRAID CP500i FH/LP:0, 1, 5, 10, 50
    • 4XC0G88835 RAID controller:5
  • Compatible products
    • PRAID CP500i FH/LP:PRIMERGY Server
    • 4XC0G88835 RAID controller:4XC0G88834

Side by side

Differences highlightedShow differences only (on)
Comparison of PRAID CP500i FH/LP, 4XC0G88835
18 specifications
Ports & interfacesidentical
Supported storage drive interfacesKnown for oneSAS, Serial ATA IIIUnknown — not stated by the source
Host interfaceKnown for onePCI Express x8Unknown — not stated by the source
PCI Express slots versionKnown for one3.0Unknown — not stated by the source
Internal mini-SAS HD portsKnown for one2Unknown — not stated by the source
Performance2 differ
RAID Level MigrationKnown for oneYesUnknown — not stated by the source
RAID levelsDiffers0, 1, 5, 10, 505
Data transfer rateKnown for one12 Gbit/sUnknown — not stated by the source
Number of devices supportedKnown for one8Unknown — not stated by the source
S.M.A.R.T. supportKnown for oneYesUnknown — not stated by the source
Compatible productsDiffersPRIMERGY Server4XC0G88834
CertificationKnown for oneUnknown — not stated by the sourceCB, FCC, EMC, C-tick, GS, CUL, UL, CE
System requirementsidentical
Server operating systems supportedKnown for oneUnknown — not stated by the sourceWindows Server 2008 R2, Windows Server 2008 R2 x64, Windows Server 2012, Windows Server 2012 R2, Windows Server 2012 R2 x64, Windows Server 2012 x64, Windows Small Business Server 2011, Windows Small Business Server 2011 x64
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source10 - 35 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source10 - 90%
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source10 mm
DepthKnown for oneUnknown — not stated by the source9 mm
HeightKnown for oneUnknown — not stated by the source14 mm
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source84733080

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More raid controller comparisons

All raid controller comparisons