Product comparison · 2 rack cooling equipment

Middle Atlantic 50 CFM Fan Panel vs Vertiv CRV CRD102

Add a product
  • 10specifications compared
  • 8differ
  • 2identical
  • 15known for one product only

Key differences

The Vertiv CRV CRD102 has 40 U more rack capacity than the Middle Atlantic 50 CFM Fan Panel (42U vs 2U). The Vertiv CRV CRD102 has 1,833 cfm more maximum airflow than the Middle Atlantic 50 CFM Fan Panel (1883 cfm vs 50 cfm). The Vertiv CRV CRD102 has 10 V more input voltage than the Middle Atlantic 50 CFM Fan Panel (230 V vs 220 V). Only the Vertiv CRV CRD102 has built-in display. Certification: CE on the Middle Atlantic 50 CFM Fan Panel, CE, RoHS on the Vertiv CRV CRD102.

  • Rack capacity
    • 50 CFM Fan Panel:2U
    • CRV CRD102:42U
  • Built-in display
    • 50 CFM Fan Panel:No
    • CRV CRD102:Yes
  • Maximum airflow
    • 50 CFM Fan Panel:50 cfm
    • CRV CRD102:1883 cfm
  • Certification
    • 50 CFM Fan Panel:CE
    • CRV CRD102:CE, RoHS
  • Input voltage
    • 50 CFM Fan Panel:220 V
    • CRV CRD102:230 V
  • Width
    • 50 CFM Fan Panel:482.6 mm
    • CRV CRD102:300 mm
  • Depth
    • 50 CFM Fan Panel:86.4 mm
    • CRV CRD102:1132 mm
  • Height
    • 50 CFM Fan Panel:88.9 mm
    • CRV CRD102:2000 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of IUQFP-2, CRV CRD102
25 specifications
A

Middle Atlantic

50 CFM Fan Panel

Model IUQFP-2

View product
Performance4 differ
Housing colourBlackBlack
Rack capacityDiffers2U42U
Cooling capacity in watts (max)Known for oneUnknown — not stated by the source3200 W
Built-in displayDiffersNoYes
Maximum airflowDiffers50 cfm1883 cfm
CertificationDiffersCECE, RoHS
Number of fansKnown for one2 fan(s)Unknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one24 dBUnknown — not stated by the source
Power1 differ
Input powerKnown for oneUnknown — not stated by the source3200 W
Input voltageDiffers220 V230 V
Input frequencyKnown for oneUnknown — not stated by the source50 Hz
Number of input phasesKnown for oneUnknown — not stated by the source1
Weight & dimensions3 differ
WidthDiffers482.6 mm300 mm
DepthDiffers86.4 mm1132 mm
HeightDiffers88.9 mm2000 mm
WeightKnown for oneUnknown — not stated by the source231 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceChina
Harmonized System (HS) code8538909985389099
Shipping (inner) case widthKnown for oneUnknown — not stated by the source77.6 cm
Shipping (inner) case lengthKnown for oneUnknown — not stated by the source127.6 cm
Shipping (inner) case heightKnown for oneUnknown — not stated by the source2.23 m
Shipping (inner) case gross weightKnown for oneUnknown — not stated by the source313 kg
Technical detailsidentical
Compliance certificatesKnown for oneCEUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one1.81 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.