Product comparison · 2 rack cooling equipment

APC ACRH301S rack cooling equipment vs Middle Atlantic 1 RU BlowerPanel, 100 CFM

Add a product
  • 9specifications compared
  • 7differ
  • 2identical
  • 12known for one product only

Key differences

The APC ACRH301S rack cooling equipment has 41 U more rack capacity than the Middle Atlantic 1 RU BlowerPanel, 100 CFM (42U vs 1U). The Middle Atlantic 1 RU BlowerPanel, 100 CFM has 182.6 mm more width than the APC ACRH301S rack cooling equipment (482.6 mm vs 300 mm). The APC ACRH301S rack cooling equipment has 838.5 mm more depth than the Middle Atlantic 1 RU BlowerPanel, 100 CFM (1095 mm vs 256.5 mm). Input voltage: 100 - 240 V on the APC ACRH301S rack cooling equipment, 220 V on the Middle Atlantic 1 RU BlowerPanel, 100 CFM. Compliance certificates: CE, UL, RCM on the APC ACRH301S rack cooling equipment, CE on the Middle Atlantic 1 RU BlowerPanel, 100 CFM.

  • Rack capacity
    • ACRH301S rack cooling equipment:42U
    • 1 RU BlowerPanel, 100 CFM:1U
  • Input voltage
    • ACRH301S rack cooling equipment:100 - 240 V
    • 1 RU BlowerPanel, 100 CFM:220 V
  • Compliance certificates
    • ACRH301S rack cooling equipment:CE, UL, RCM
    • 1 RU BlowerPanel, 100 CFM:CE
  • Width
    • ACRH301S rack cooling equipment:300 mm
    • 1 RU BlowerPanel, 100 CFM:482.6 mm
  • Depth
    • ACRH301S rack cooling equipment:1095 mm
    • 1 RU BlowerPanel, 100 CFM:256.5 mm
  • Height
    • ACRH301S rack cooling equipment:1991 mm
    • 1 RU BlowerPanel, 100 CFM:44.5 mm
  • Package weight
    • ACRH301S rack cooling equipment:226.5 kg
    • 1 RU BlowerPanel, 100 CFM:2.36 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of ACRH301S, IQBP-2A
21 specifications
B

Middle Atlantic

1 RU BlowerPanel, 100 CFM

Model IQBP-2A

View product
Performance1 differ
Rack capacityDiffers42U1U
AirflowKnown for one1374.3 l/sUnknown — not stated by the source
Number of fansKnown for oneUnknown — not stated by the source2 fan(s)
Maximum airflowKnown for oneUnknown — not stated by the source100 cfm
Noise levelKnown for oneUnknown — not stated by the source30 dB
CertificationKnown for oneUnknown — not stated by the sourceCE
Power1 differ
Input powerKnown for one930 WUnknown — not stated by the source
Input voltageDiffers100 - 240 V220 V
Input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Technical details1 differ
Compliance certificatesDiffersCE, UL, RCMCE
Weight & dimensions3 differ
WidthDiffers300 mm482.6 mm
DepthDiffers1095 mm256.5 mm
HeightDiffers1991 mm44.5 mm
WeightKnown for one186.5 kgUnknown — not stated by the source
Packaging data1 differ
Package widthKnown for one661 mmUnknown — not stated by the source
Package depthKnown for one1095 mmUnknown — not stated by the source
Package heightKnown for one2265 mmUnknown — not stated by the source
Package weightDiffers226.5 kg2.36 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85389099

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More rack cooling equipment comparisons