Product comparison · 2 rack cooling equipment

APC ACRD301S rack cooling equipment vs Vertiv Liebert HCR43

Add a product
  • 12specifications compared
  • 11differ
  • 1identical
  • 7known for one product only

Key differences

The Vertiv Liebert HCR43 has 281,728.73 l/s more airflow than the APC ACRD301S rack cooling equipment (283333.33 l/s vs 1604.6 l/s). The Vertiv Liebert HCR43 has 250 W more input power than the APC ACRD301S rack cooling equipment (1100 W vs 850 W). The Vertiv Liebert HCR43 has 2,040 mm more width than the APC ACRD301S rack cooling equipment (2340 mm vs 300 mm). Housing colour: Black on the APC ACRD301S rack cooling equipment, Aluminium on the Vertiv Liebert HCR43.

  • Housing colour
    • ACRD301S rack cooling equipment:Black
    • Liebert HCR43:Aluminium
  • Airflow
    • ACRD301S rack cooling equipment:1604.6 l/s
    • Liebert HCR43:283333.33 l/s
  • Input power
    • ACRD301S rack cooling equipment:850 W
    • Liebert HCR43:1100 W
  • Width
    • ACRD301S rack cooling equipment:300 mm
    • Liebert HCR43:2340 mm
  • Depth
    • ACRD301S rack cooling equipment:1095 mm
    • Liebert HCR43:1112 mm
  • Height
    • ACRD301S rack cooling equipment:1991 mm
    • Liebert HCR43:910 mm
  • Weight
    • ACRD301S rack cooling equipment:160 kg
    • Liebert HCR43:92 kg
  • Package width
    • ACRD301S rack cooling equipment:661 mm
    • Liebert HCR43:1195 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD301S, HCR43
19 specifications
B

Vertiv

Liebert HCR43

Model HCR43

View product
Performance2 differ
Housing colourDiffersBlackAluminium
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
AirflowDiffers1604.6 l/s283333.33 l/s
Built-in displayNoNo
CertificationKnown for oneUnknown — not stated by the sourceCE
Rack capacityKnown for one42UUnknown — not stated by the source
Power1 differ
Input powerDiffers850 W1100 W
Input voltageKnown for oneUnknown — not stated by the source230 V
Input frequencyKnown for oneUnknown — not stated by the source50 Hz
Number of input phasesKnown for oneUnknown — not stated by the source1
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers300 mm2340 mm
DepthDiffers1095 mm1112 mm
HeightDiffers1991 mm910 mm
WeightDiffers160 kg92 kg
Packaging data4 differ
Package widthDiffers661 mm1195 mm
Package depthDiffers1137 mm2420 mm
Package heightDiffers2152 mm1100 mm
Package weightDiffers200 kg142 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.